QUICK REFERENCE CONTENTS

Each of the main front or rear panel accessible features of the PFM-500 is illustrated below, along with the page number 

where information on that particular feature is located.

Chassis Ground:

Page 8

Return/Ground:

Page 5

Status Contacts:

Page 7

Hot Switched Outputs:

Page 6

Status Contacts: 

Page 7

Hot Power Module

Input: Page 7

Hot Unswitched

Output: Page 6 

Chassis GND

Switched Outputs

1

2

3

4

5

TO REDUCE THE RISK  

OF ELECTRIC SHOCK,  

DISCONNECT POWER  

BEFORE OPENING COVER

OUTPUT

INPUT (POWER MODULE) 

HOT

BATTERY

POSITIVE, NEGATIVE, OR FLOATING GROUND

STATUS CONTACTS

RETURN/

GND

INPUT

1

INPUT

2

INPUT

3

LVD

SUMMARY 

ALARM 

OUTPUT

INPUT

4

INPUT 

5

INPUT 

6

NC NO C

•• •

CONTACTS 

SHOWN IN 

FAILED  

POSITION

1    2    3

1    2    3

1    2    3

1    2    3

1    2    3

1    2    3

1    2    3

1    2    3

1    2    3

1    2    3

PRE

LVD

WARNING!

Hot Battery Input/Output: 

Page 5

LCD DISPLAY:  

Page 11

Menu Knob:  

Page 10

TEMPERATURE 

SENSOR: Page 4

LVD Selector: 

Page 10

Circuit Breaker Installation

Ports: Page 8

NEWPORT BEACH, CA USA

www.newmarpower.com

E-MAIL: [email protected]

TEL: (714) 751-0488

FAX: (714) 957-1621

POWER FUNCTION MANAGER

Model: PFM-500

INPUT:

+12, +24, -48 VDC

500 AMPS MAX

MENU

ALARM

LOW VOLTAGE

BATTERY  

DISCONNECT

AUTO

METER  

POWER 

SOURCE

MANUAL  

CONNECT

MANUAL  

DISCONNECT

BATTERY 

 

RECTIFIER

FIGURE 2: PFM REAR PANEL

POWER SOURCE SELECTOR:  

Page 10

ALARM LED:  

Page 12

FIGURE 1: PFM FRONT PANEL

Summary Alarm 

Contacts: Page 7

Pre-LVD Activation 

Alarm: Page 11

Содержание PFM-500

Страница 1: ...ng E Output Wiring 5 1 Unswitched Output 2 Switched Output F Battery Wiring 6 G Status and Alarm Contact Wiring 7 H Chassis Grounding 8 I Circuit Breakers 8 1 Breaker Installation 2 Breaker Functions...

Страница 2: ...TERY POSITIVE NEGATIVE OR FLOATING GROUND STATUS CONTACTS RETURN GND INPUT 1 INPUT 2 INPUT 3 LVD SUMMARY ALARM OUTPUT INPUT 4 INPUT 5 INPUT 6 NC NO C CONTACTS SHOWN IN FAILED POSITION 1 2 3 1 2 3 1 2...

Страница 3: ...osing flush mounting C Bus Bar Mounting The PFM is shipped with a rackmount ground bus bar assembly kit BBA 800 The bus bar is typically mounted on the rear of the rack and is designed for installatio...

Страница 4: ...Hot Wire to POSITIVE OUTPUT Terminal Positive Ground Systems Connect Ground Wire to POSITIVE OUTPUT Terminal and Hot Wire to NEGATIVE OUTPUT Terminal Power Plugs shown present only if using NEWMAR QC...

Страница 5: ...for proper PFM input wire gauges 3 A return ground wire must also be run from the BBA bus bar or other grounding point to the terminal on the PFM labeled RETURN GND This is not a system ground rather...

Страница 6: ...s requires installation of a model PBA plug in breaker available from NEWMAR at that position See section II I Fig 7 for installation details and breaker functions See section VII for available ampera...

Страница 7: ...ness is designed for installations which employ NEWMAR Power Modules though it may be modified for use with other types of equipment as well provided they are equipped with Form C or Normally Open N O...

Страница 8: ...nd a summary alarm from the DST is required this may be accomplished through parallel wiring of the status wires Please contact the factory for information on how to perform this modification When wir...

Страница 9: ...reaker receptacle and pushing firmly into place The two top auxiliary contact terminals in the middle of the breaker should press against the mating clips The bottom auxiliary contact is unused in thi...

Страница 10: ...e or the battery side by using the selector switch on front panel Powering the meter from the rectifier side default causes the PFM 500 to completely shutdown during a Low Battery Voltage Disconnect t...

Страница 11: ...8 Fax 714 856 9679 E Mail techservice newmarpower com PoweringTheNetwork com C LCD Display 1 Digital Meter Programming Sequence Flow Chart Figure 8 Digital Meter Programming Sequence Flow Chart see pa...

Страница 12: ...voltage disconnect Screen press programming button to enter set mode rotate knob to change push to confirm setting See page 13 for detailed directions 4B LVD voltage connect Screen press programming...

Страница 13: ...ngs and is retained even after powering down the unit LVD threshold adjustment can be made while the system is operating 3 LVD Alarms Pre disconnect disconnect Two external alarms can be triggered by...

Страница 14: ...Section III D for LVD adjustment procedure 4 PFM load circuit breaker tripped Breaker is in mid trip position Note Breaker will not activate the ALARM L E D if manually switched into the off position...

Страница 15: ...power com Anytime We are happy to consult with you to resolve any problems or questions you may have If during consultation it appears the PFM must be returned to the factory for repair we will issue...

Страница 16: ...low TEMPERATURE RATING 0 C to 60 C CASE SIZE H x W x D 3 5 x 19 or 23 x 20 5 LVD SPECIFICATIONS Factory set actuation voltages 12 Volt 24 Volt 48 Volt Disconnect 10 4V DC 21 0V DC 42 0V DC Connect 12...

Отзывы: