© 2021 Copyright Newmar Corporation. All rights reserved. For the most up-to-date version of this content, and for more product-specific information, please refer to Newgle.
177
PLUMBING
Operation
To shower while dry camping, follow these steps:
1. Press the Aqua Miser LT button on the LCD
touchscreen. The LED indicator light will turn blue
inside the translucent mushroom cover when the
water temperature is cold.
2. Place the Aqua Miser lever in the “recycle” position.
This will divert the water back to the fresh tank
instead of wasting the water and filling the grey tank.
The blue LED light will turn off and the red LED will
turn on when the water gets hot.
3. When the light turns red, the system is ready for final
shower temperature adjustments to be made. Turn
the diverter valve back to the water flow position.
4. Turn the shower mixing valve (rotating knob on
the right side of the shower pipe) until the desired
temperature has been reached.
5. To alternate between the wand and shower head, use
the rotating knob on the left side of the shower pipe.
This knob also selects the water output intensity.
If left in the diverted/recycle position while the coach
is connected to city water, the Aqua Miser system will
continue to add water to the tank if the fresh water
fill valve in the water compartment is turned to the
auto fill or auto city supply position. Adding water to
the fresh tank in this manner is unregulated and may
cause the fresh tank to overflow, which may make the
auto fill system appear as though it is malfunctioning.
IMPORTANT
!
Winterizing the Aqua View Fresh Water Reclamation
System
This article provides additional winterization instructions relevant to coaches equipped with an Aqua View Shower Miser
Fresh Water Reclamation System. This information should be used in conjunction with the coach winterization process as
written in Newgle.
Do not leave the valve in bypass mode when running
antifreeze in the line because it will allow antifreeze
into the fresh tank.
IMPORTANT
!
•
Cycle the valve to the recirculate position to purge
the water out of the line back to the fresh water tank
while pressurized air supply is connected.
•
Place the valve back to normal flow mode to the
shower head.
•
Then purge the shower.
•
Run RV antifreeze through the shower system.
Содержание LONDONAIRE 2022
Страница 1: ...SM 2022...