73
ELECTRICAL
Checking Battery Status
During inverter operation (in battery mode), you can
check the battery status by observing the battery capacity
indicator on the LCD screen. The battery voltage appears
in the left side of LCD screen. The normal operating
battery voltage range is between 11 and 15 volts.
Checking Output Power
When the inverter is in operation (in battery mode),
you can check how much power (displayed in Amps)
the Freedom X is supplying to the connected loads by
observing the load capacity indicator on the LCD screen.
The battery discharge amperage appears in the right side
of the LCD screen.
Operating Several Loads At
Once
If you are going to operate several loads from the
Freedom X, turn them on one at a time after you have
turned the inverter on. Turning loads on separately helps
to ensure that the inverter does not have to deliver the
starting current for all the loads at once, and will help
prevent an overload shutdown.
To prevent unnecessary battery discharge, press the
inverter Power button to turn it off when you are not using
the Freedom X.
WARNING
!
ELECTRICAL SHOCK HAZARD: Turning the inverter
Power button off does not disconnect DC battery
power from the Freedom X. You must disconnect
both AC and DC power before working on any
circuits connected to the unit. Failure to follow these
instructions can result in death or serious injury.
Turning The Audible Alarm On
or Off
The Freedom X’s audible alarm can be silenced. Any
warnings such as fault conditions or imminent shutdown
are both displayed on the LCD screen and sounded on
the alarm speakers. It is not possible to turn OFF the
screen and prevent it from displaying error codes but it is
possible to turn OFF the audible alarm.
To reset the alarm:
•
Press the inverter Power button to turn it Off (from a
down position to up) and press again to turn it On to
reset an active alarm and clear the fault.
Source(s): Xantrex Freedom XC Series Inverter Charger Owner’s Guide
Product(s): Xantrex 1200 watt Pure Sine Freedom Inverter (Model: 806-1212,
Newmar Part Number: 144620) and Xantrex True Sine 2000 Watt Inverter (Model:
817-2080, Newmar Part Number: 145171)
Resetting AC Output
The 15 amp resettable breaker is located on the inverter
near the outlet.
Interior Lights
Interior and Exterior Lights
A Newmar coach’s electrical and lighting system is designed for maximum reliability, functionality, and style.
Lighting
A Newmar coach’s electrical and lighting system is
designed for maximum reliability, functionality, and style.
Your coach may feature traditional on/off switches or
multi-switch touch panel light and accessory switch
panels. Located throughout the unit, these switching
devices are used to turn lights on and off, as well as to
operate power shades and window treatments. Many
coach models boast LED accent lights and LED wall
sconces custom-designed for Newmar.
Provides basic information about operation, maintenance, and replacement of interior and exterior lights.
Flip the switch or touch the switch panel to operate the
light or accessory you desire. Some lights may also have
dimming features, allowing you to adjust the interior
lighting for mood or comfort. For more details about the
interior lights, refer to the documentation in Newgle.
When replacing halogen bulbs, do not touch the bulb,
as the oil from your hands will reduce the bulb’s life.
IMPORTANT
!