![New Rock Technologies WROC2000 Скачать руководство пользователя страница 66](http://html.mh-extra.com/html/new-rock-technologies/wroc2000/wroc2000_user-manual_1678086066.webp)
66
Remote Management
This feature enables you to access the WROC at a WAN port address remotely.
Setting Remote Management
To set remote management, perform the following steps:
1.
Click
Mgmt
on the home page.
2.
Navigate to
Remote Management
.
5.
In
Remote management
, select
Enable
.
Note:
This procedure is not available in bridge mode.
6.
In
Access method
, select
https
or
http
. You can also modify
Remote management port
(the
default value is 8080).
7.
Set the
IP range of remote PC
specified for the PCs that are allowed to remotely visit the device.
The default range is 0.0.0.0 to 255.255.255.255, which allows any terminal to visit the device.
8.
Click
Save
.
9.
Remote access to WROC:
e
nter
http://xxx.xxx.xxx.xxx:port
or
https://xxx.xxx.xxx.xxx:port
in the
address bar of the Web browser, in which xxx.xxx.xxx.xxx is the WAN IP address or DDNS of WROC
and port is the remote management port.
If the
Access method
is
https
,
after clicking
login
,
WROC will send a certificate which may be blocked by the Web browser for the reason of
untrusting. Trust this certificate will enable you to access the Web login page of WROC2000.
Port Capture
This feature is used for troubleshooting media related issues, such as CID detection failure or busy
tone detection failure .Port capture records the media stream from the analog line. The capturing
starts from the off-hook of a phone interface or from the ringing of a line interface, and it is ended
upon on-hook. Only the first 200 seconds of media stream is captured and data captured afterwards
will be discarded. The captured data will be saved on WROC2000 as PCMU format file.
1.
Click
Mgmt
on the home page.
2.
Navigate to
System tool >Port capture
3.
Enter the
Extension number
or Click to select the
Analog line ID
or
Extension number
you want
to perform the capture, then click
Apply
. The call for port capture has to be completed in 200
seconds from the establishment of the calling on the line.
4.
Click
Start
to initiate the capture procedure.
5.
Make the test call (Outbound call for Phone port, inbound call for Line port).
6.
Click
Stop
to finish the capture procedure.
7.
A downloading request window will pop up to allow you to download the captured data to your
PC.
8.
Send the captured file or related issue description to
. Our technicians will
help you to analyze and solve the issue.
Data Packet Capture
This feature is used for troubleshooting IP packet related issues, such as one-way voice, noise or echo.
Содержание WROC2000
Страница 1: ...1 WROC2000 Wireless Office Communication System User Manual Applicable to Version 2 1 5 88 ...
Страница 6: ...6 Chapter I Overview ...
Страница 7: ...7 Overview Front View Rear View ...
Страница 10: ...10 Chapter II Getting Started ...
Страница 13: ...13 Chapter III Network ...
Страница 34: ...34 Chapter IV Voice ...
Страница 63: ...63 Chapter V Management ...
Страница 69: ...69 ...