User Manual MX Series Voice Gateway
86 New Rock Technologies, Inc.
Table 2-34 Access security setting parameters
Name
Description
Change
administrator
/operator password
Set the administrator/operator password by entering the current password.
The password must meet the following requirements:
8 to 16 characters
At least two of the following: letters, numbers, and symbols
Excluding&, =, and “
Please change the initial password at first time login.
Web
HTTP/HTTPS port
Set the HTTP/HTTPS port for the device. The default value is 80 for HTTP and 443 for
HTTPS.
HTTP/HTTPS port is use for:
Web accessing (XML command interface)
Auto Provisioning
Login time out
Set the login timeout interval, the default value is 600s.
If you do not conduct any
operation within timeout interval, you will log out.
SSH
Enable SSH
If this parameter is selected, terminals are allowed to access the device through SSH. It is not
selected by default.
When accessing the device through SSH, you should login with user
operator
, and use
su root
command to change to user
root
.
Please disable SSH in time after accessing is finished.
SSH port
Set the SSH port for the device. The default value is 22.
Change SSH
password
Set password of user
root
or
operator.
Password must meet the following requirements:
6 to 20 characters
At least the two of following: English letters, numbers, and symbols
Excluding & = “
Ping
Inbound Ping request
Block or unblock the Ping requests. The device block the ping requests by default.
2.7.2 Access list
Access list is used to specify the source addresses which are allowed to access the device through Web GUI
(HTTP/HTTPS) or SSH.
After login, click
Security
>
Access list
to open the configuration interface.
Once access list is enabled, only addresses specified here are allowed to access the device through
Web GUI or SSH.