MX Series Voice Gateway User Manual
New Rock Technologies, Inc.
39
Figure 2-7
SIP Configuration Interface
Table 2-7 SIP Configuration Parameters
Name
Description
Local signaling
port
Configure the UDP port for transmitting and receiving SIP messages, with its default value 5060.
Note: The signaling port number can be set in the range of 1-9999, but cannot conflict with the
other port numbers used by the equipment.
Increments of
port number
If "n" (ranked from 1-10) is chosen, after the failure registration of signaling port’s original
configuration, the variation of signaling port’s change ranges from the original signaling port to the
original signaling port +n". Register with the new signaling port value (signaling port +1) until it
succeeds.
Registrar server
Configure the address and port number of the SIP registration server. The address and port number
are separated by “:”. It has no default value.
The register server address can be an IP address or a domain name.
e.g. 168.33.134.51:5000 or www.sipproxy.com:5000.
When a domain name is used, you must activate DNS service and configure DNS server parameters
on the network-configuration page.
Proxy server
Configure the IP address and port number of the SIP proxy server. The address and port number are
separated by “:”. It has no default value.
The proxy server address can be set to an IP address or a domain name.
e.g. 168.33.134.51:5000 or www.sipproxy.com:5000.
When a domain name is used, you must activate DNS service and configure DNS server parameters
on the network-configuration page.
When a domain name is used, you can fill in a backup IP address in
Backup SIP proxy server
in
the High Availability configuration. This allows the device to failover to the IP address if the
domain name resolution service fails.
Subdomain
name
This domain name will be used in INVITE messages. If it is not set here, the gateways will use the
IP address or domain name of the proxy server as the user-agent domain name. It has no default
value.