User Manual MX Series Voice Gateway
54 New Rock Technologies, Inc.
Name
Description
Hook flash time
max
Used by gateway to detect hook flash, the default is 800 milliseconds.
The gateway will regard the flash duration between
Hook flash time min
and
Hook flash time
max
as effective flash. Any flash lasting over the longest time will be considered by gateway as
hang up. Generally, this value should not be less than 800 milliseconds.
Caller ID
transmission mode
Select transmission mode of Caller ID signal from the FXS port to the phone.
FSK or DTMF
SDMF or MDMF
Sending Caller ID data before or after ringing
Sending Caller ID data with or without parity
Hook debouncing
Used by gateway to avoid phone status errors, with default of 50 milliseconds.
When the duration from hang-up to off-hook falls short of this value, the gateway will ignore the
status variation, and consider that the phone remains in hang-up status. In opposite case, the
gateway will ignore the status variation, and consider the phone remains in off-hook status.
Effective range of setting is 10~1000 milliseconds.
Ring frequency
Set the ringing frequency to be transmitted by gateway to the phone, ranging from 15 to 50 Hz,
with default of 20 Hz.
Play busy tone for
network fault
Play a busy tone upon off-hook when a network fault occurs.
Caller release
Set the delay release time of line as caller control method, with a default of 60 seconds. Effective
range of setting is 15~180 seconds.
This parameter is used in combination with the
Release control by caller
parameter in
Line
>
Feature
.
Outpulsing delay
Used when gateway’s FXS port is connected with the trunk interface of PBXs. For calls from
gateway to PBX, gateways will relay the extensions to PBX after the delay set here. Setting of 0
means no extension number relay. The default is
0
milliseconds.
Loop open interval
This parameter is used with the loop open disconnection request. The range is from 100 ms to
6000 ms.
Polarity reversal
Set the trigger for polarity reversal, the default is
Outgoing.
Outgoing
: transmit reverse polarity signal only when the outbound is connected;
Bi-direction
: transmit reverse polarity signal for the connection of both inbound and out
bound calls.
Polarity reversal
delay
The delay time from a call being answered to the transmission of reverse polarity signal. The
default value is 3 in seconds. Effective range of setting is 0 - 30 seconds.
Music on hold
Choose whether to play the background music while call waiting. This is not selected by default.
Call waiting with
hunt group
Choose whether to activate hunt group feature for call waiting. Default not selected.
Message waiting
indication (MWI)
Select the lighting method of message waiting indicator of voice mail here: None, Polarity
reversed, FSK, high voltage lighting.
Message waiting indicator refers to the special LED on a phone that lights up upon receiving a
voice message. It is essential to understand whether the phone supports the indicator and lighting
method when selecting the lighting method.
Hotline dialing relay
This parameter specifies the delay time before the preset hotline number is automatically dialed
after hook-off. The default value is 5 seconds, and the value range is 2 to 20 seconds. This
parameter works only if the delay mode is set for hotline function on
Line
>
Feature
page. See
Pulse detection
Enable it to support connecting with a rotary dial phone.
Distinctive
Alert/Ringing
Set the parameter
Alert-Infon
according to the “Alert-Info” value provided on the SIP server.
When the “Alert-info” value of received INVITE message matches with the
Alert-Infon
, ring
cadence
n
is activated.
Alert-Info 1
Match with ring cadence 1.