5 Menu tree
5.8 MAIN MENUE – Doors
FST-2_HB.EN12/05
141
Doors selective –
Opening time
Opening time of a car door without limit switch. If car doors
without limit switches are used, the inputs for the door limit
switches must be bridged (see “FSM: X7” on page 58 and
“FSM: X9” on page 59). The opening time of car doors without
limit switches must be measured exactly and entered here.
The value should be set to 20 seconds for doors with limit
switches (see “Door times diagram” on page 143).
0 .. 20 sec
Doors selective –
Decoupling
Car doors that allow the door leaf to be decoupled. If this
parameter is activated, the controller checks the door limit
switches and the safety circuit and recognizes if the door
leaves are decoupled. It then tries re-coupling the door leaves
by repeatedly opening the doors. This parameter can only be
activated with working door limit switches.
YES
NO
Doors selective –
Decouple Max
Maximum re-coupling attempts when the door leaves are
decoupled before all calls are deleted (only relevant if
Decoupling = YES
).
0 .. 10
Doors selective –
Manual door
Shaft doors are manual revolving doors. Door C input of the
safety circuit is used to query the manual door contact
(display:
MANUAL DOOR OPEN
).
YES
NO
Doors selective –
Man. door deb.
Debounce time of the manual door contacts. This parameter
prevents “scatter” at the retiring cam output when starting due
to bouncing manual door contacts.
0 .. 5 sec
Doors selective –
Nudging
If no nudging outputs are used to decrease the closing speed
of the doors during nudging (
Nudging output = NO
),
pulsed nudging can be triggered. The door close call is issued
as a pulse so the door closes in steps. The Cycle time of the
nudging pulses can be set here. If the photocell is interrupted
longer than the time set in
Doors selective – Door
nudging
, the door will be closed with pulsed nudging.
0 .. 6 sec
Doors selective –
Limit switches
The car door has limit switches (end switches).
-
YES: Connect car door limit switches to FSM X6 and X10.
Set
Opening time
to 20 seconds.
-
NO: The limit switch inputs FSM X6 and X10 are not
required, opening time = time actually required for opening
the car door.
See “FSM: X6” on page 58, “FSM: X10” on page 59 and “Door
times diagram” on page 143.
Pay attention to jumpers J21, J31, J71 and J81 on the FSM
(see FSM “J21” on page 55).
YES
NO
Doors selective –
Photocell
Maximum number of consecutive reversing cycles of the car
door caused by photocell interruptions before forced closing
(nudging). This parameter is normally set to 0 (function
disabled). Only set this parameter to a value higher than 0
after consulting NEW LIFT!
0 .. 10
Doors selective –
Photocell Xtn
Internal extension of the photocell signal by the controller
software. This parameter enables complete opening of the
door after a photocell interruption.
0.0 .. 10.0 sec
Doors selective –
Open hold time
The time doors are held open if there are no car or landing
calls. This parameter is only effective if no further calls are
pending. The door opening time with pending calls is
controlled by
Min. Wait Landing / Min. Wait
Car
(see “Door times diagram” on page 143).
2 .. 250 sec
Doors selective –
Reversing time
Opening time of the car door after a reversing cycle.
0.0 .. 20.0 sec
Menu item
Description
Setting
Содержание FST-2
Страница 6: ...Table of contents 4 FST 2_HB EN12 05...
Страница 98: ...5 Menu tree 5 1 General 96 FST 2_HB EN12 05 Fig 5 1 FST 2 Controller menu tree part 1...
Страница 99: ...5 Menu tree 5 1 General FST 2_HB EN12 05 97 Fig 5 2 FST 2 Controller menu tree part 2...
Страница 100: ...5 Menu tree 5 1 General 98 FST 2_HB EN12 05 Fig 5 3 FST 2 Controller menu tree part 3...
Страница 101: ...5 Menu tree 5 1 General FST 2_HB EN12 05 99 Fig 5 4 FST 2 Controller menu tree part 4...
Страница 102: ...5 Menu tree 5 1 General 100 FST 2_HB EN12 05 Fig 5 5 FST 2 Controller menu tree part 5...
Страница 103: ...5 Menu tree 5 1 General FST 2_HB EN12 05 101 Fig 5 6 FST 2 Controller menu tree part 6...
Страница 104: ...5 Menu tree 5 1 General 102 FST 2_HB EN12 05 Fig 5 7 FST 2 Controller menu tree part 7...
Страница 105: ...5 Menu tree 5 1 General FST 2_HB EN12 05 103 Fig 5 8 FST 2 Controller menu tree part 8...
Страница 112: ...5 Menu tree 5 3 MAIN MENU Drive 110 FST 2_HB EN12 05 Fig 5 10 Drive with speed correction function...
Страница 133: ...5 Menu tree 5 5 MAIN MENU Positioning FST 2_HB EN12 05 131 Fig 5 13 Parameters for linear positioning...
Страница 134: ...5 Menu tree 5 5 MAIN MENU Positioning 132 FST 2_HB EN12 05 Fig 5 14 Additional parameters for incremental positioning...
Страница 140: ...5 Menu tree 5 7 MAIN MENUE System 138 FST 2_HB EN12 05 Event channels Fig 5 16 Event channels of the FST 2 Controller...
Страница 174: ...6 Programmable inputs and outputs 172 FST 2_HB EN12 05...