
5 Menu tree
5.3 MAIN MENU – Drive
FST-2_HB.EN12/05
107
Speed correction function
If the drive is equipped with a speed correction function, this
parameter can be activated to optimise floor to floor travel (see
page 109).
YES
NO
Emergency stop: Car calls
Handling of pending car calls after a safety circuit interruption
in the emergency stop area (before terminal 33) while the car
was moving.
KEEP
DELETE
Emergency stop: Stop
Handling of landing calls after a safety circuit interruption in
the emergency stop area (before terminal 33) while the car
was moving.
-
YES: Landing calls are blocked. The car can only be moved
with a car command.
-
NO: Pending landing calls are deleted. Landing calls will be
enabled again after the safety circuit has been closed.
YES
NO
Homing time
Maximum time without a car call before an hydraulic lift travels
to the lowest floor automatically.
0 .. 15 min
Contactor monitoring
Monitoring of the main contactors on FST X1 terminal 23 via
auxiliary contacts (normally closed). When stopping, input
FST X1 terminal 23 must be activated during the set
Contactor Mon. Time
(+24V). If this fails, the system
will be shut down with
DRM-CONTACTOR MON.
(see
“DRM-CONTACTOR MONIT.” on page 178).
YES
NO
Contactor Mon. Time
Delay between stopping and activation of the contactor
monitoring function.
0 .. 9999 msec
Delay monitoring
Monitoring of the delay at end floors
YES
NO
Change time
Minimum delay when switching the main contactors (fast to
slow) of unregulated lift motors.
0 .. 0.5 sec
Stop Max
Maximum number of door contact or locking device
interruptions (terminals 37 and 40) during a drive before all
calls will be deleted (see “
The system will not be shut down, it is waiting for new calls.
0 .. 10
Pawl Control
Function
Activate Pawl Control control for hydraulic building hoists.
Additional modules are required for Pawl Control control (see
system description of the Pawl Control).
OFF
ON
OPTIMISED
Pawl Control
Hydr.Unit
Hydraulic aggregate (see system description of the Pawl
Control).
GIEHL
BER.ELRV
OILDYNAM
LEISTRITZ
Pawl Control
Raise distance
Lifting distance for extending/retracting the Pawl Control (see
description of the Pawl Control).
0 .. 255 mm
Pawl Control
Raise Time Max
Maximum lifting time (see system description of the Pawl
Control).
0 .. 255 sec
Pawl Control
Solenoid Pawl
Activate the electric (not hydraulic) Pawl Control (see
description of the Pawl Control).
YES
NO
Pawl Control
Door-Lock
Block doors when the Pawl Control is retracted (see system
description of the Pawl Control).
YES
NO
Pawl Control
Fine pump UP
Activate additional pump for lifting (see system description of
the Pawl Control).
YES
NO
Pawl Control
Fine pump DN
Activate additional valve for lowering (see system description
of the Pawl Control).
YES
NO
Pawl Control
Low Press. Ctrl
Re-pump to avoid slack in the cable with the car loaded (see
system description of the Pawl Control).
YES
NO
Menu item
Description
Setting range
Содержание FST-2
Страница 6: ...Table of contents 4 FST 2_HB EN12 05...
Страница 98: ...5 Menu tree 5 1 General 96 FST 2_HB EN12 05 Fig 5 1 FST 2 Controller menu tree part 1...
Страница 99: ...5 Menu tree 5 1 General FST 2_HB EN12 05 97 Fig 5 2 FST 2 Controller menu tree part 2...
Страница 100: ...5 Menu tree 5 1 General 98 FST 2_HB EN12 05 Fig 5 3 FST 2 Controller menu tree part 3...
Страница 101: ...5 Menu tree 5 1 General FST 2_HB EN12 05 99 Fig 5 4 FST 2 Controller menu tree part 4...
Страница 102: ...5 Menu tree 5 1 General 100 FST 2_HB EN12 05 Fig 5 5 FST 2 Controller menu tree part 5...
Страница 103: ...5 Menu tree 5 1 General FST 2_HB EN12 05 101 Fig 5 6 FST 2 Controller menu tree part 6...
Страница 104: ...5 Menu tree 5 1 General 102 FST 2_HB EN12 05 Fig 5 7 FST 2 Controller menu tree part 7...
Страница 105: ...5 Menu tree 5 1 General FST 2_HB EN12 05 103 Fig 5 8 FST 2 Controller menu tree part 8...
Страница 112: ...5 Menu tree 5 3 MAIN MENU Drive 110 FST 2_HB EN12 05 Fig 5 10 Drive with speed correction function...
Страница 133: ...5 Menu tree 5 5 MAIN MENU Positioning FST 2_HB EN12 05 131 Fig 5 13 Parameters for linear positioning...
Страница 134: ...5 Menu tree 5 5 MAIN MENU Positioning 132 FST 2_HB EN12 05 Fig 5 14 Additional parameters for incremental positioning...
Страница 140: ...5 Menu tree 5 7 MAIN MENUE System 138 FST 2_HB EN12 05 Event channels Fig 5 16 Event channels of the FST 2 Controller...
Страница 174: ...6 Programmable inputs and outputs 172 FST 2_HB EN12 05...