40
Consumable Replacement
The user can estimate the timing of battery recharging by checking the battery level
indicator on the LCD. When the battery is drained, “Battery Empty” will be displayed
on the LCD, the unit will beep, and the detector will not detect gases any longer.
The LCD will then turn off when the batteries are completely drained.
Filter Element Replacement
Replace the filter element with a new one if it is dirty or wet. If water is present inside
the drain filter or filter case, remove the water and clean the drain filter or filter case.
Replace the filter element for the drain filter
(1)
Separate the filter case from the drain filter by turning the case counterclockwise.
(2)
Remove the gasket (O-ring) from the filter case by using a small screwdriver etc.
(3)
Replace the filter element (FE-2) with a new one.
(4)
Reinstall the filter case to the drain filter.
Do not replace the filter element while the detector is in
operation, to prevent foreign matter (e.g., dust, sand) from
entering inside the unit.
Ensure that the filter element is installed correctly.
Misalignment may compromise gas detection and
waterproof performance.
Call for repair if water is observed to be inside. Proper gas
detection is not possible if water is present inside the gas
detector.
Do not push or poke the filter element with a finger etc.
Deformation or breakage of the filter element may
compromise its waterproof function.
NOTE
Gasket
Filter element (FE-2)
Filter case
Drain filter
WARNING