4
Introduction
Explosion-proof Requirements
Follow the conditions below to comply with the explosion-proof requirements.
Models which use non-rechargeable alkaline AA batteries:
ATEX: II 1G Ex ia da IIC T4 Ga
(Other than XP-3380II)
II 1G Ex ia IIC T4 Ga
(XP-3380II)
IECEx: Ex ia da IIC T4 Ga
(Other than XP-3380II)
Ex ia IIC T4 Ga
(XP-3380II)
UL:
Class I, Division 1, Groups A, B, C and D;
Class l, Zone0 AEx da ia llC Ga
(Other than XP-3380II)
Class I, Division 1, Groups A, B, C and D;
Class l, Zone0 AEx ia llC Ga
(XP-3380II)
Model
s
which use rechargeable nickel metal hydride AA batteries:
ATEX:
II 1G Ex ia da IIC T3 Ga
(Other than XP-3380II)
II 1G Ex ia IIC T3 Ga
(XP-3380II)
IECEx: Ex ia da IIC T3 Ga
(Other than XP-3380II)
Ex ia IIC T3 Ga
(XP-3380II)
UL:
Class I, Division 1, Groups A, B, C and D;
Class l, Zone0 AEx da ia llC Ga
(Other than XP-3380II)
Class I, Division 1, Groups A, B, C and D;
Class l, Zone0 AEx ia llC Ga
(XP-3380II)
The device has a temperature code of T4 when used with primary cells or
T3 when used with secondary cells.
ATEX certificate No.:
CML 20ATEX2035X for gas detectors
IECEx certificate No.: IECEx CML 20.0017X for gas detectors
UL certificate No.:
E108302
for gas detectors
ATEX certificate No.:
CML 19ATEX1374U for combustible gas sensors
IECEx certificate No.:
IECEx CML 19.0118U
for combustible gas sensors
UL certificate No.:
E108302
for combustible gas sensors
Standards: (ATEX) EN60079-0: 2018
EN60079-1: 2014
EN60079-11: 2012
(IECEx) IEC 60079-0: 2017 Edition 7.0
IEC 60079-1: 2014 Edition 7.0
IEC 60079-11: 2011 Edition 6.0
(UL)
UL 60079-0 : 7th Edition
UL 60079-1 : 7th Edition
UL 60079-11 : 6th Edition
UL 913 :8th Edition
Electrial data: Four 1.5 V alkaline AA batteries, two in parallel and two in series, or
Four 1.3 V nickel metal hydride AA batteries, two in parallel and two in
series.