48
9.
Specifications
■
Product Specifications
Model
XP-3310II, XP-3318II, XP-3340II, XP-3360II-W, XP-3368II-W, XP-
3360II, XP-3368II, XP-3380II, XP-3380II-E
Target gas
As per Table 9-1
Detection principle
As per Table 9-1
Sensor operation method
Continuous
Gas sampling method
Extractive
Measuring range
(Service range
*1
)
As per Table 9-1
Accuracy
*2
(Service range excluded)
As per Table 9-1
Resolution
As per Table 9-1
Gas alarm set value
As per Table 9-1
Response time
*3
As per Table 9-1
Gas alarm method
Beeping with blinking red light and “AL” icon on the LCD
Device error notification
Beeping with blinking yellow light and error message on the LCD
Power source
・
Non-rechargeable alkaline AA battery x4: Toshiba LR6, Panasonic
LR6X, Duracell MN1500, Energizer E91 or Varta 4106
・
Rechargeable nickel metal hydride AA battery x4: New Cosmos
HR-3UTG
Continuous operation time
*4
As per Table 9-1
Operating
temperature/humidity
-20
C
to +50
C
0 to 95%RH
No condensation. No sudden change in temperature or humidity.
Operating pressure
Atmospheric pressure (800 to 1100 hPa)
Compliance
Models which use non-rechargeable alkaline AA batteries:
ATEX: II 1G Ex ia da IIC T4 Ga (Other than XP-3380II)
II 1G Ex ia IIC T4 Ga
(XP-3380II)
IECEx: Ex ia da IIC T4 Ga
(Other than XP-3380II)
Ex ia IIC T4 Ga
(XP-3380II)
UL:
Class I, Division 1, Groups A, B, C and D;
Class l, Zone0 AEx da ia llC Ga (Other than XP-3380II)
Class I, Division 1, Groups A, B, C and D;
Class l, Zone0 AEx ia llC Ga (XP-3380II)
The device has a temperature code of T4 when used with
primary cells or T3 when used with secondary cells.
Models which use rechargeable nickel metal hydride AA batteries:
ATEX:
II 1G Ex ia da IIC T3 Ga (Other than XP-3380II)
II 1G Ex ia IIC T3 Ga
(XP-3380II)
IECEx: Ex ia da IIC T3 Ga
(Other than XP-3380II)
Ex ia IIC T3 Ga
(XP-3380II)
UL:
Class I, Division 1, Groups A, B, C and D;
Class l, Zone0 AEx da ia llC Ga (Other than XP-3380II)
Class I, Division 1, Groups A, B, C and D;
Class l, Zone0 AEx ia llC Ga (XP-3380II)
The device has a temperature code of T4 when used with
primary cells or T3 when used with secondary cells.
CE (ATEX, EMC, RoHS, RE and LVD, directives)
(Continued on next page)