6
6 INSTALLATION DIAGRAMS
NetZero Fire Waterplace devices are designed to take in air from either vents in the top of the unit, or
vents. If the top vents are obstructed with any decorative media, you must allow free air into the
surround from below. The waterplace can intake air from the side vents but requires a 50 square inches
of air intake into the cutout cavity for each 20 inches of unit length. This is commonly done by venting in
a recessed toe kick below the cavity.
In the enclosure, a 120V (min. 12 amp) electric outlet must be installed to plug in the 24-volt
transformer.
If connecting the waterplace to a water supply line the water line must also be run into the enclosure.
See the diagram below for the enclosure dimensions.
You must leave 2 inches (50mm) minimum around the device to facilitate installation.
6.1 Enclosure Dimensions
Models
A Length
B Width
C Height
NZW20B
20-1/4 in
12-3/16 in
10 in
NZWP20B
20-1/4 in
12-3/16 in
12 in
NZW40B
40-1/4 in
12-3/16 in
10 in
NZWP40B
40-1/4 in
12-3/16 in
12 in
NZW60B
60-1/4 in
12-3/16 in
10 in
NZWP60B
60-1/4 in
12-3/16 in
12 in
Note: If using the optional kit to connect water direct to the Waterplace Series the height must be
increased to 12 inches. Waterplace Platinum burners include the required components to connect to a
water supply line.