background image

 

 

11 

7. Information about Battery Passivation 

Many of Netvox devices are powered by 3.6V ER14505 Li-SOCl2 (lithium-thionyl chloride) batteries that offer many 

advantages including low self-discharge rate and high energy density.      

 

However, primary lithium batteries like Li-SOCl2 batteries will form a passivation layer as a reaction between the lithium 

anode and thionyl chloride if they are in storage for a long time or if the storage temperature is too high. This lithium chloride 

layer prevents rapid self-discharge caused by continuous reaction between lithium and thionyl chloride, but battery passivation 

may also lead to voltage delay when the batteries are put into operation, and our devices may not work correctly in this situation.    

 

As a result, please make sure to source batteries from reliable vendors, and it is suggested that if the storage period is more 

than one month from the date of battery production, all the batteries should be activated. 

 

 

If encountering the situation of battery passivation, users can activate the battery to eliminate the battery hysteresis. 

 

ER14505 Battery Passivation: 

7.1 To determine whether a battery requires activation 

Connect a new ER14505 battery to a resistor in parallel, and check the voltage of the circuit. 

If the voltage is below 3.3V, it means the battery requires activation.   

 

7.2 How to activate the battery 

a. Connect a battery to a resistor in parallel   

b. Keep the connection for 5~8 minutes 

c. The voltage of the circuit should be 

3.3, indicating successful activation. 

 

Brand 

Load Resistance 

Activation Time 

Activation Current 

NHTONE 

165 Ω

 

5 minutes 

20mA 

RAMWAY 

67 Ω

 

8 minutes 

50mA 

EVE 

67 Ω

 

8 minutes 

50mA 

SAFT 

67 Ω

 

8 minutes 

50mA 

Note:   

If you buy batteries from other than the above four manufacturers,  then the battery activation time, activation current, and 

required load resistance shall be mainly subject to the announcement of each manufacturer. 

Содержание R718PQA

Страница 1: ...Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without written permission of NETVOX Technology The specifications are subject to change without prior notice ...

Страница 2: ... Example of ReportDataCmd 6 5 2 Example of ConfigureCmd 6 5 3 Example for MinTime MaxTime logic 8 6 IR Disable Time and Detection Time 10 7 Information about Battery Passivation 11 7 1 To determine whether a battery requires activation 11 7 2 How to activate the battery 11 8 Important Maintenance Instruction 12 ...

Страница 3: ...odulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building automation equipment wireless security systems industrial monitoring Main features include small size low power consumption transmission distance anti interference ability and so on LoRaWAN LoRaWAN uses LoRa technology to...

Страница 4: ...ameters can be configured through third party software platforms data can be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Low power consumption and long battery life Note Battery life is determined by the sensor reporting frequency and other variables please refer to http www netvox com tw electric electric_calc ...

Страница 5: ...on for 5 seconds success The green indicator remains off fail Had joined the network not at factory setting Turn on the device to search the previous network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Fail to join the network when the device is on Suggest to check the device verification information on the gateway or consult your platform server...

Страница 6: ...detected every Min Interval Battery change 0x01 0 1V Disable time 30s Detection time 5min If there is special custom shipment the setting is changed according to customer s requirements IRDisableTime must 5 s and IRDectionTime IRDisableTime Occupancy alarm If there are movements of people animals or any organism in the detected area the infrared sensor detects the infrared signal And if the closin...

Страница 7: ...voxPayLoadData Fixed bytes Fixed 8bytes Uplink 0197012201000000000000 Byte Value Attribute Result Resolution 1st 01 Version 1 2nd 97 DeviceType 97 3rd 01 ReportType 1 4th 22 Battery 3 4v 22 HEX 34 DEC 34 0 1v 3 4v 5th 01 Status on 6th 11th 000000000000 Reserved 5 2 Example of ConfigureCmd FPort 0x07 Bytes 1 1 Var Fix 9 Bytes CmdID DeviceType NetvoxPayLoadData CmdID 1 byte DeviceType 1 byte Device ...

Страница 8: ...s Reserved 8Bytes Fixed 0x00 Get IRDisableTImeReq 0x04 Reserved 9Bytes Fixed 0x00 Get IRDisableTImeRsp 0x84 IRDisableTime 2bytes Unit s IRDectionTime 2bytes Unit s Reserved 5Bytes Fixed 0x00 1 Configure device parameters MinTime 1min MaxTime 1min BatteryChange 0 1v Downlink 0197003C003C0100000000 Device returns 8197000000000000000000 configuration succeeded 8197010000000000000000 configuration fai...

Страница 9: ...ange 0 1V MaxTime sleeping sleeping 0H 15th M 30th M 45th M 1H 1H 10th M 1H 25th M 1H 40th M 1H 55th M 2H 10th M Wakes up and collects data 3 6V Does not report Wakes up and collects data 3 6V Does not report Wakes up and collects data 3 6V Does not report Wakes up and collects data REPORTS 3 6V Wakes up and collects data REPORT 3 6V Wakes up and collects data REPORTS 3 6V Wakes up and collects da...

Страница 10: ...ts according to MinTime interval If the data variation is not greater than the last data reported the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter resulting from data variation button pu...

Страница 11: ...1 30 70 seconds to save the power living objects within this period will not be detected PIR will re open detection function after 21 seconds if it detects living objects in this period the IR delay time will be extended for another 30 seconds till no infrared signal is detected and IRDetectionTime period is due and R718PQA will then report un occupy Note IRDisableTime 5 s IRDetectionTime IRDisabl...

Страница 12: ...ge period is more than one month from the date of battery production all the batteries should be activated If encountering the situation of battery passivation users can activate the battery to eliminate the battery hysteresis ER14505 Battery Passivation 7 1 To determine whether a battery requires activation Connect a new ER14505 battery to a resistor in parallel and check the voltage of the circu...

Страница 13: ...melt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Rough handling of equipment can destroy internal circuit boards and delicate structures Do not clean the device with strong chemicals detergents or strong detergents Do no...

Отзывы: