background image

 

 

4. Set up Instruction 

On/Off 

 

Power on 

Insert batteries. (users may need a screwdriver to open) 

Turn on   

Press and hold the function key for 3 seconds till the green indicator flashes once.   

Turn off

 

(Restore to factory setting) 

Press and hold the function key for 5 seconds till green indicator flashes for 20 times. 

Power off 

Remove Batteries.   

Note: 

1. Remove and insert the battery; the device is at off state by default. 

2. On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor   

inductance and other energy storage components. 

3. At 1

st

 -5

th

 second after power on, the device will be in engineering test mode.   

Network Joining 

 

Never joined the network 

Turn on the device to search the network to join. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

Had joined the network 

(not at factory setting) 

Turn on the device to search the previous network to join. 

The green indicator stays on for 5 seconds: success 

The green indicator remains off: fail 

Fail to join the network   

(when the device is on) 

Suggest to check the device verification information on the gateway or consult your 

platform server provider. 

Function Key 

 

Press and hold for 5 seconds 

Restore to factory setting / Turn off 

The green indicator flashes for 20 times: success 

The green indicator remains off: fail 

Press once   

The device is in the network: green indicator flashes once and sends a report 

The device is not in the network: green indicator remains off 

Sleeping Mode 

 

The device is on and in the 

network 

Sleeping period: Min Interval. 

When the reportchange exceeds setting value or the state changes: send a data report 

according to Min Interval.   

Low Voltage Warning 

Low Voltage 

3.2V 

 

 

Содержание R718PQA

Страница 1: ...Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without written permission of NETVOX Technology The specifications are subject to change without prior notice ...

Страница 2: ... Example of ReportDataCmd 6 5 2 Example of ConfigureCmd 6 5 3 Example for MinTime MaxTime logic 8 6 IR Disable Time and Detection Time 10 7 Information about Battery Passivation 11 7 1 To determine whether a battery requires activation 11 7 2 How to activate the battery 11 8 Important Maintenance Instruction 12 ...

Страница 3: ...odulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building automation equipment wireless security systems industrial monitoring Main features include small size low power consumption transmission distance anti interference ability and so on LoRaWAN LoRaWAN uses LoRa technology to...

Страница 4: ...ameters can be configured through third party software platforms data can be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Low power consumption and long battery life Note Battery life is determined by the sensor reporting frequency and other variables please refer to http www netvox com tw electric electric_calc ...

Страница 5: ...on for 5 seconds success The green indicator remains off fail Had joined the network not at factory setting Turn on the device to search the previous network to join The green indicator stays on for 5 seconds success The green indicator remains off fail Fail to join the network when the device is on Suggest to check the device verification information on the gateway or consult your platform server...

Страница 6: ...detected every Min Interval Battery change 0x01 0 1V Disable time 30s Detection time 5min If there is special custom shipment the setting is changed according to customer s requirements IRDisableTime must 5 s and IRDectionTime IRDisableTime Occupancy alarm If there are movements of people animals or any organism in the detected area the infrared sensor detects the infrared signal And if the closin...

Страница 7: ...voxPayLoadData Fixed bytes Fixed 8bytes Uplink 0197012201000000000000 Byte Value Attribute Result Resolution 1st 01 Version 1 2nd 97 DeviceType 97 3rd 01 ReportType 1 4th 22 Battery 3 4v 22 HEX 34 DEC 34 0 1v 3 4v 5th 01 Status on 6th 11th 000000000000 Reserved 5 2 Example of ConfigureCmd FPort 0x07 Bytes 1 1 Var Fix 9 Bytes CmdID DeviceType NetvoxPayLoadData CmdID 1 byte DeviceType 1 byte Device ...

Страница 8: ...s Reserved 8Bytes Fixed 0x00 Get IRDisableTImeReq 0x04 Reserved 9Bytes Fixed 0x00 Get IRDisableTImeRsp 0x84 IRDisableTime 2bytes Unit s IRDectionTime 2bytes Unit s Reserved 5Bytes Fixed 0x00 1 Configure device parameters MinTime 1min MaxTime 1min BatteryChange 0 1v Downlink 0197003C003C0100000000 Device returns 8197000000000000000000 configuration succeeded 8197010000000000000000 configuration fai...

Страница 9: ...ange 0 1V MaxTime sleeping sleeping 0H 15th M 30th M 45th M 1H 1H 10th M 1H 25th M 1H 40th M 1H 55th M 2H 10th M Wakes up and collects data 3 6V Does not report Wakes up and collects data 3 6V Does not report Wakes up and collects data 3 6V Does not report Wakes up and collects data REPORTS 3 6V Wakes up and collects data REPORT 3 6V Wakes up and collects data REPORTS 3 6V Wakes up and collects da...

Страница 10: ...ts according to MinTime interval If the data variation is not greater than the last data reported the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter resulting from data variation button pu...

Страница 11: ...1 30 70 seconds to save the power living objects within this period will not be detected PIR will re open detection function after 21 seconds if it detects living objects in this period the IR delay time will be extended for another 30 seconds till no infrared signal is detected and IRDetectionTime period is due and R718PQA will then report un occupy Note IRDisableTime 5 s IRDetectionTime IRDisabl...

Страница 12: ...ge period is more than one month from the date of battery production all the batteries should be activated If encountering the situation of battery passivation users can activate the battery to eliminate the battery hysteresis ER14505 Battery Passivation 7 1 To determine whether a battery requires activation Connect a new ER14505 battery to a resistor in parallel and check the voltage of the circu...

Страница 13: ...melt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shake the device Rough handling of equipment can destroy internal circuit boards and delicate structures Do not clean the device with strong chemicals detergents or strong detergents Do no...