channel, specified by a user at the page of a web interface. YYYY –
is a name of a relay management mode. The next modes are possible:
«switched off manually», «switched on manually», «watchdog management», «schedule management», «schedule and watchdog management»,
«logic management».
PWR: relay N "XXXX" is switched to the mode "YYYY" by a command via SMS – is recorded into the log file when switching a relay management
mode using SMS commands. N – is a number of a power management channel. XXXX – is a description of a power management channel,
specified by a user at the page of a web interface. YYYY – is a name of a relay management mode. The next modes are possible: «switched off
manually», «switched on manually», «watchdog management», «schedule management», «schedule and watchdog management», «logic
management».
EVENTS FRO
M POWER SUPPLY INPUTS
PWR: sockets N are switched to the input X – is recorded into the log file when an input for a group of sockets is switched directly. N – is a group
of sockets with the next possible values: «1-4» and «5-8». X – is a number of an input, possible values are «1» and «2».
PWR:
N sockets via a web interface
an input X without backup is set to feed
– is recorded into the log file when installing the main input for a
group of sockets via a device web interface as well as in the moment of disabling a parameter
. N – is a group of
«Switch to the backup input»
sockets. The next values are possible: «1-4» and «5-8». X – is an input number, its possible values are: «1» and «2».
– is recorded into the log file in the moment of disabling the
PWR:
to feed N sockets using an SMS command
an input X without the backup is set
parameter «Switch to the backup input
. N – is a group of sockets. The next values are possible: «1-4» and «5-8». X –
» using an SMS command
is
: «1» and «2».
an input number, its possible values are
PWR: a
N sockets via a web interface, backup without auto return
main input X is set to feed
– is recorded into the log file in the moment of setting
the parameter
.
«Switch to the backup input» in a web interface N – is a group of sockets. The next values are possible: «1-4» and «5-8». X – is an
input number, its possible values are: «1» and «2».
PWR: a main input X is set to feed N sockets using an SMS command, backup without auto return – is recorded into the log file in the moment of
setting the parameter «Switch to a backup input» using an SMS command. N – is a group of sockets. The next values are possible: «1-4» and
«5-8». X – is an input number, its possible values are: «1» and «2».
PWR: a main input X is set to feed N sockets via a web interface, backup with an auto return – is recorded into the log file in the moment of setting
the parameter «Autoreturn to a main input» in a web interface. N – is a group of sockets. The next values are possible: «1-4» and «5-8». X – is an
input number, its possible values are: «1» and «2».
PWR: a main input X is set to feed
– is recorded into the log file in the moment of
N sockets using an SMS command, backup with auto return
setting the parameter «Autoreturn to a main input» using an SMS command. N – is a group of sockets. The next values are possible: «1-4» and
«5-8». X – is an input number, its possible values are: «1» and «2».
PWR: a command to return N sockets to a main input (X) is received via a web interface – is recorded into the log file in the moment of a manual
return to a main input in a device web interface. N – is a group of sockets. The next values are possible: «1-4» and «5-8». X – are input numbers,
possible values are: «1->2» and «2->1».
PWR: a command to return N sockets to a main input (X) is received using an SMS command – is recorded into the log file in the moment of a
manual return to a main input using an
. N – is a group of sockets, the next values are possible: «1-4» and «5-8». X – are input
SMS command
numbers, possible values are: «1->2» and «2->1».
– is recorded into the log file in the moment of a manual return
PWR: a command to return N sockets to a main input (X) is received by running cgi
to a main input by
.
URL-encoded commands (HTTP API) N – is a group of sockets, the next values are possible: «1-4» and «5-8». X – are input
numbers, possible values are: «1->2» and «2->1».
PWR: voltage appeared at the input X – is recorded into the log file when a voltage appeared at the input X of a device. X – is an input number,
possible values are: «1» and «2».
PWR: voltage disappeared at the input X – is recorded into the log file when a voltage disappeared at the input X of a device. X – is an input
number, possible values are: «1» and «2».
EVENTS FROM THE MODULE FOR SENDING E-MAIL NOTIFICATIONS
sendmail: YYYY received in response to XXXX – is recorded into the log file if a server returns «incorrect» response code. XXXX – is a service
information: an authentication method or a message recipient. YYYY – is an error notification.
sendmail: email discarded – is recorded into the log file if it is impossible to send e-mail notification to an SMTP server.
No room for new mail message XXXX – is recorded into the log file if notification queue is overflown. XXXX – is a client's request and a server's
.
response
EVENTS OF GSM MODEM OPERATION
Manual restart of a GSM modem through a web interface – is recorded into the log file in the moment of running a procedure of a manual
reloading a GSM modem by a user in a device web interface.
GSM modem is ready for operation – is recorded into the log file after a GSM modem has been initialized in the system.