8-Port Gigabit (PoE+) Ethernet Smart Managed Pro Switch with (2 SFP or 2 Copper Ports and)
Cloud
Management
Maintain or Troubleshoot the Switch
User Manual
455
For information about the credentials, see
Credentials for the local browser interface on
5.
Click the
Login
button.
The System Information page displays.
6.
Select
Maintenance > Troubleshooting > Ping IPv6
.
7.
From the
Ping
menu, select the type of ping:
•
Global
. Pings a global IPv6 address.
•
Link Local
. Pings a link-local IPv6 address over a specified interface. With this
selection, the
Interface
menu displays, and you must select the interface.
8.
In the
IPv6 Address/Hostname
field, enter the IPv6 address or host name of the station
that must be pinged.
The format is xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx. The maximum number of
characters is 255.
9.
In the
Count
field, enter the number of echo requests that must be sent.
The range is 1 to 15. The default value is 3.
10.
In the
Interval
field, enter the time in seconds between ping packets.
The range is 1 to 60. The default value is 3.
11.
In the
Datagram Size
field, enter the datagram size.
The valid range is 0 to 13000. The default value is 0 bytes.
12.
From the
Source
menu, as an option, you can select the IP address or interface that must
be used to send echo request packets:
•
None
. The source address of the ping packet is the address of the default egress
interface.