Ness R8
- Installation and Programming Manual
29
PROGRAMMING
All zones can be programmed to Lockout, i.e. cause the RESET
OUTPUT to sound only once whilst the panel is armed.
The RESET OUTPUT is then locked out for that alarmed zone until
entering a valid code has reset the panel.
PROGRAMMING SEQUENCE
1. Press:
P44E
2. Press:
[1-8] E
to toggle each zone on or off.
Zone light/s on indicates which option/s are enabled.
PROGRAM MODE LEVEL:
Installer, Remote by PC.
FACTORY DEFAULT:
1–8 = ON, All zones are
Lockout zones.
NOTES:
• This option applies to the
RESET output, the SIREN
output always locks out.
RELATED OPTIONS:
P60E 4E, Tamper Reset
Lockout.
P44E
RESET LOCKOUT ZONES
This option selects which zones will be armed in Monitor mode.
Monitor zones allow you to Arm selected zones while others are
ignored. Typically used for perimeter zones such as windows and
doors while you are at home. Example: Upstairs zones are Disarmed
while downstairs zones are Armed in Monitor mode.
PROGRAMMING SEQUENCE
1. Press:
P51E
2. Press:
[1-8] E
to toggle each zone on or off.
Zone light/s on indicates which option/s are enabled.
PROGRAM MODE LEVEL:
Installer, Remote by PC.
FACTORY DEFAULT:
1–8 = OFF, No Monitor zones.
RELATED OPTIONS:
P64E 1E, Brief Monitor alarm.
P51E
MONITOR ZONES
24hr Zones operate at all times regardless of the mode of panel
operation, i.e. Armed, Disarmed or Monitor. When alarmed, these
zones will activate assigned outputs immediately. To reset a 24hr
zone alarm, a valid user code must be entered.
Selecting a zone as 24hr will override any other zone type setting
such as Instant, Delayed or Handover.
PROGRAMMING SEQUENCE
1. Press:
P52E
2. Press:
[1-8] E
to enable each zone for this option.
• To deselect a zone from this option, program it to be Delayed,
Instant or Handover.
• Zone light/s on indicates which option/s are enabled.
PROGRAM MODE LEVEL:
Installer, Remote by PC.
FACTORY DEFAULT:
1–8 = OFF, No 24hr zones.
NOTES:
• The Tamper input is always
a 24hr zone
P52E
24HR ZONES