Dimensions

112(h) x 72(w) x 48(d) mm

Mounting height

2.1m ~ 2.3m

Coverage

Up to 15m x 15m @ 90°

Detection zones

20 quad element zones

Pulse count

Selectable 1–2 or 3–4

Range

Selectable High/Low. 15m max./12m max.

Sensor

Quad element pyroelectric

Alarm indication

blue alarm LED

Relay output

Solid state relay, normally closed contacts, 100mA max.

Tamper output

Normally closed switch

FAST output
SENS output 

Open collector (pulls to 0V/Neg)

Light In input 

Pull low to 0V/Neg to activate

Night-Light

White LED with adjustable threshold, Dark/Dim Light

Alarm period

2 seconds

Warm up period

30 seconds

Operating voltage

10 ~ 15V DC

Current draw

10mA

Compatibility

All hardwired control panels

sPecIFIcatIons

OPTIONAL ACCESSORIES
QUANTUM SWIVEL bRACkET can be used to provide 
wall or ceiling mounting with a wide range of vertical and 
horizontal adjustment. 
Part No. 100-243

Содержание LUX

Страница 1: ...activated night light Adjustable Digital Pulse Count Adjustable Digital Range High R F and E S D immunity High white light immunity High quality patented Fresnel lens Capsule design with sealed electronics Front cover tamper protection Totally silent solid state relay with high immunity to magnetic fields Optional mounting bracket available REV1 LUX Hardwired Installation Notes Ness LUX wired PIR ...

Страница 2: ...ht light only in the dark Ness LUX s capsule design protects sensitive electronic components and provides easy access to the terminals and dipswitches Detection Coverage At the recommended mounting height of 2 1m 2 3m LUX detector coverage is up to 15m HIGH range setting or 12m LOW range setting Pet Aware Mode In Pet Aware mode see Settings the lower detection zones are masked by the sensor mask w...

Страница 3: ...sensor do not touch Dipswitches for custom settings Encapsulated design for easy removal and protection of the PCB Tamper switch 3 position sensor mask White night light LED Blue alarm LED also glows behind the lens PIR lens do not paint or cover Vertical creep zone Ambient light sensor PCB locking tabs each side squeeze both tabs to remove the capsule ...

Страница 4: ... Remove the capsule to keep it safe while you install the back housing 3 Drill out a cable entry hole at the top of the LUX back housing The cable entry hole hole should be small enough for a tight cable fit to prevent insects entering the sensor The housing has cable channel to allow mounting on hard surfaces with cable entry top or bottom 4 Install the LUX back housing to the wall using four scr...

Страница 5: ...on and flips up from the bottom as per the diagrams below Please ensure that the sensor mask is in the correct position for the required mode ie for Pet Aware mode select dipswitch 3 on and move the sensor mask to position 3 Position 1 Normal Detection Mode default Position 2 No Creep Zone Mode Position 3 Pet Aware Mode 3 position Sensor Mask Lift up to adjust ...

Страница 6: ...e Alarm LED OFF The Alarm LED is disabled ON The Alarm LED is enabled Default Switch 5 Light Mode Sets the operation of the white night light LED Manual Manual control of the night light using the Light In terminal Auto Automatic operation of the night light Default means the night light will activate when movement is detected in darkness In this mode manual control is also allowed us ing the Ligh...

Страница 7: ... Level dipswitch This output may be connected in parallel with Sensor Out terminals on other LUX PIRs if required The output is OFF when the room is illumi nated Eg Daytime or light ON The output is ON pulls to 0V when the room is dark FAST OUT This output indicates movement in the protect ed area regardless of the pulse count setting This is useful for home automation and light control where a no...

Страница 8: ...max Sensor Quad element pyroelectric Alarm indication Blue alarm LED Relay output Solid state relay normally closed contacts 100mA max Tamper output Normally closed switch FAST output SENS output Open collector pulls to 0V Neg Light In input Pull low to 0V Neg to activate Night Light White LED with adjustable threshold Dark Dim Light Alarm period 2 seconds Warm up period 30 seconds Operating volta...

Отзывы: