background image

3

coMPonents

White Night Light LED

Ambient light sensor 
behind lens

DIP Switch and masking 
instructions  

Inputs / Outputs

blue alarm LED

Quad element pyro sensor 
(do not touch)

Dipswitches for custom 
settings

Encapsulated design for easy 
removal and protection of 
the PCb

Tamper switch

3 position sensor mask

White night-light LED

blue alarm LED - also 

glows behind the lens

PIR lens  

(do not paint or cover)

Vertical creep zone

Ambient light sensor

PCb locking tabs each 

side / squeeze both tabs 

to remove the capsule

Содержание LUX

Страница 1: ...activated night light Adjustable Digital Pulse Count Adjustable Digital Range High R F and E S D immunity High white light immunity High quality patented Fresnel lens Capsule design with sealed electronics Front cover tamper protection Totally silent solid state relay with high immunity to magnetic fields Optional mounting bracket available REV1 LUX Hardwired Installation Notes Ness LUX wired PIR ...

Страница 2: ...ht light only in the dark Ness LUX s capsule design protects sensitive electronic components and provides easy access to the terminals and dipswitches Detection Coverage At the recommended mounting height of 2 1m 2 3m LUX detector coverage is up to 15m HIGH range setting or 12m LOW range setting Pet Aware Mode In Pet Aware mode see Settings the lower detection zones are masked by the sensor mask w...

Страница 3: ...sensor do not touch Dipswitches for custom settings Encapsulated design for easy removal and protection of the PCB Tamper switch 3 position sensor mask White night light LED Blue alarm LED also glows behind the lens PIR lens do not paint or cover Vertical creep zone Ambient light sensor PCB locking tabs each side squeeze both tabs to remove the capsule ...

Страница 4: ... Remove the capsule to keep it safe while you install the back housing 3 Drill out a cable entry hole at the top of the LUX back housing The cable entry hole hole should be small enough for a tight cable fit to prevent insects entering the sensor The housing has cable channel to allow mounting on hard surfaces with cable entry top or bottom 4 Install the LUX back housing to the wall using four scr...

Страница 5: ...on and flips up from the bottom as per the diagrams below Please ensure that the sensor mask is in the correct position for the required mode ie for Pet Aware mode select dipswitch 3 on and move the sensor mask to position 3 Position 1 Normal Detection Mode default Position 2 No Creep Zone Mode Position 3 Pet Aware Mode 3 position Sensor Mask Lift up to adjust ...

Страница 6: ...e Alarm LED OFF The Alarm LED is disabled ON The Alarm LED is enabled Default Switch 5 Light Mode Sets the operation of the white night light LED Manual Manual control of the night light using the Light In terminal Auto Automatic operation of the night light Default means the night light will activate when movement is detected in darkness In this mode manual control is also allowed us ing the Ligh...

Страница 7: ... Level dipswitch This output may be connected in parallel with Sensor Out terminals on other LUX PIRs if required The output is OFF when the room is illumi nated Eg Daytime or light ON The output is ON pulls to 0V when the room is dark FAST OUT This output indicates movement in the protect ed area regardless of the pulse count setting This is useful for home automation and light control where a no...

Страница 8: ...max Sensor Quad element pyroelectric Alarm indication Blue alarm LED Relay output Solid state relay normally closed contacts 100mA max Tamper output Normally closed switch FAST output SENS output Open collector pulls to 0V Neg Light In input Pull low to 0V Neg to activate Night Light White LED with adjustable threshold Dark Dim Light Alarm period 2 seconds Warm up period 30 seconds Operating volta...