6
swItcH 1 - range
Sets the detector’s sensitivity. Low range is
recommended for coverage of areas under
than 12m.
Low
Low range, 12m max coverage.
(Default)
High
High range, 15m max coverage.
swItcH 2 - PuLse
Sets the detector’s pulse count.
3–4
3–4 Pulses or walk steps should cause
an alarm. (Default)
1–2
1–2 Pulses or walk steps should cause
an alarm.
swItcH 3 - Pet
Enables Pet Aware mode which tunes the
response and sensitivity for pet immunity.
OFF
Normal mode. Set the sensor mask in
position 1 or 2. (Default)
ON
Pet Aware mode.
the sensor mask must be in position 3
when Pet aware mode on enabled.
settIngs
Ness LUX custom settings are set by dipswitches 1-6. The dipswitches are easily accessible on the
sensor capsule.
Use a small screwdriver or pen tip to set the switches.
swItcH 4 - Led
Enables the blue Alarm LED.
OFF
The Alarm LED is disabled.
ON
The Alarm LED is enabled. (Default)
swItcH 5 - LIgHt Mode
Sets the operation of the white night-light LED.
Manual
Manual control of the night-light using
the Light In terminal.
Auto
Automatic operation of the night-light
(Default) means the night-light will activate
when movement is detected in darkness. In
this mode, manual control is also allowed us-
ing the Light In terminal.
In Auto mode and for one hour after power-up,
the night-light will operate along with the blue
LED to provide an extra bright light source for
walk-tesing.
swItcH 6 - LIgHt LeveL
Sets the light level at which LUX’s ambient light
sensor will enable the night-light.
Light
The night-light will operate when the
ambient lighting is semi-dark. (Default)
Dark
The night-light will operate only when
the ambient lighting is very low or near total
darkness.
SW NAME
OFF
ON
1 Range
Low
High
2
Pulse
3-4
1-2
3 Pet
Normal
Pet
4
Alarm LED
Off
On
5 Light Mode
Manual Auto
6
Light level
Light
Dark