background image

4

MountIng LocatIon

The Ness LUX hardwired PIR is designed for indoor 
use  only  and  can  be  installed  in  wall  or  corner 
mount locations.
LUX is designed to be wall or corner mounted at 
the optimal height of 2.1m~2.3m.
The optional Ness Quantum bracket allows LUX 
to be ceiling mounting with a wide range of tilt and 
swivel adjustment.
Always ensure the detector has a clear line of sight 
in the area to be protected as infra-red energy does 
not pass through solid objects, (including glass).
Mount the detector in a location where an intruder 
is most likely to walk across the coverage pattern. 
Corner mounting usually gives the best detection 
coverage.
As with all PIR detectors, it is advisable to choose 
mounting  positions  which  avoid  direct  sunlight, 
heating  or  cooling  sources  and  avoid  areas  of 
high  humidity  which  may  cause  condensation 
on the lens.

InstaLLatIon

1  Remove  the  lock  screw  at  the  bottom  of  the 

LUX assembly (if fitted) then using a small flat 

bladed screwdriver release the two front cover 

tabs and remove the front cover, bottom first.

2  Release the PIR capsule from the back housing 

by squeezing the two locking tabs on either side 

of the capsule. Remove the capsule to keep it 

safe while you install the back housing. 

3   Drill out a cable entry hole at the top of the LUX 

back housing. The cable entry hole hole should 

be small enough for a tight cable fit to prevent 

insects entering the sensor.

  The  housing  has  cable  channel  to  allow 

mounting on hard surfaces with cable entry top 

or bottom.

4  Install the LUX back housing to the wall using 

four screws appropriate for the surface.

  At  this  stage  any  oversized  cable  entry  or 

mounting holes should be sealed with silicone  

to prevent the entry of dirt and insects.

5  Insert the PIR capsule into the back housing and 

push gently until the two locking  tabs click into 

place.

6  Connect your power, alarm and other wiring as 

required.

7  Set the dipswitches as required. 
8  Replace the front cover and walk test the PIR. 

Fit the bottom locking screw once walk testing 

is complete.

MountIng HeIgHt

The Ness LUX hardwired PIR is designed for indoor 
use  and  can  be  wall  or  corner  mounted  at  the 
recommended height  of 2.1m~2.3m. 
LUX can be mounting at higher or lower heights at 
the installer’s discretion when using the optional 
Quantum Swivel bracket which provides tilt and 
swivel adjustment to cater for the shape or size 
of the room.
If  LUX  is  direct  mounted  without  a  bracket,  the 
installer’s choice of mounting height and position 
will entirely determine the coverage.

Содержание LUX

Страница 1: ...activated night light Adjustable Digital Pulse Count Adjustable Digital Range High R F and E S D immunity High white light immunity High quality patented Fresnel lens Capsule design with sealed electronics Front cover tamper protection Totally silent solid state relay with high immunity to magnetic fields Optional mounting bracket available REV1 LUX Hardwired Installation Notes Ness LUX wired PIR ...

Страница 2: ...ht light only in the dark Ness LUX s capsule design protects sensitive electronic components and provides easy access to the terminals and dipswitches Detection Coverage At the recommended mounting height of 2 1m 2 3m LUX detector coverage is up to 15m HIGH range setting or 12m LOW range setting Pet Aware Mode In Pet Aware mode see Settings the lower detection zones are masked by the sensor mask w...

Страница 3: ...sensor do not touch Dipswitches for custom settings Encapsulated design for easy removal and protection of the PCB Tamper switch 3 position sensor mask White night light LED Blue alarm LED also glows behind the lens PIR lens do not paint or cover Vertical creep zone Ambient light sensor PCB locking tabs each side squeeze both tabs to remove the capsule ...

Страница 4: ... Remove the capsule to keep it safe while you install the back housing 3 Drill out a cable entry hole at the top of the LUX back housing The cable entry hole hole should be small enough for a tight cable fit to prevent insects entering the sensor The housing has cable channel to allow mounting on hard surfaces with cable entry top or bottom 4 Install the LUX back housing to the wall using four scr...

Страница 5: ...on and flips up from the bottom as per the diagrams below Please ensure that the sensor mask is in the correct position for the required mode ie for Pet Aware mode select dipswitch 3 on and move the sensor mask to position 3 Position 1 Normal Detection Mode default Position 2 No Creep Zone Mode Position 3 Pet Aware Mode 3 position Sensor Mask Lift up to adjust ...

Страница 6: ...e Alarm LED OFF The Alarm LED is disabled ON The Alarm LED is enabled Default Switch 5 Light Mode Sets the operation of the white night light LED Manual Manual control of the night light using the Light In terminal Auto Automatic operation of the night light Default means the night light will activate when movement is detected in darkness In this mode manual control is also allowed us ing the Ligh...

Страница 7: ... Level dipswitch This output may be connected in parallel with Sensor Out terminals on other LUX PIRs if required The output is OFF when the room is illumi nated Eg Daytime or light ON The output is ON pulls to 0V when the room is dark FAST OUT This output indicates movement in the protect ed area regardless of the pulse count setting This is useful for home automation and light control where a no...

Страница 8: ...max Sensor Quad element pyroelectric Alarm indication Blue alarm LED Relay output Solid state relay normally closed contacts 100mA max Tamper output Normally closed switch FAST output SENS output Open collector pulls to 0V Neg Light In input Pull low to 0V Neg to activate Night Light White LED with adjustable threshold Dark Dim Light Alarm period 2 seconds Warm up period 30 seconds Operating volta...

Отзывы: