background image

9

Clock Display

Cellular Signal

to display the calendar.

Touch  

 

Touch 

 to close the window.

The date and time are normally 
displayed when the system is 
armed or disarmed.

The clock is automatically updated 
from your cellular network so you 
should only need to adjust the 
clock if the panel is being used 
‘offline’ without a SIM card

If the clock is manually set you will 
need to adjust the hours setting for 
Daylight Savings.

The date and time can be set in 
User program Mode, see page 28.

If there is a System alarm, this area 
will display the alarm. See pages 
10-11.

The cellular network signal 
strength is displayed here.

Signal strength range is 00 (no 
signal) to 30 (Best signal).

Signal strength below 5 means 
the antenna should be checked or 
moved to a better reception area.

Signal strength 00 and a 

cellular 

Fail

 message could mean that a 

valid SIM card is not fitted or the 
cellular network is not available.

no siM

 means there is no SIM 

card fitted.

Содержание K-9220

Страница 1: ...Touch Screen Keypad Navigator Touch Screen Keypad for use with D8XCEL D16XCEL 4G panels User s Manual Rev 1 12 Document 890 498 Ness SIM information see page 40 SIM ...

Страница 2: ...esence of in band radio signals high power transmissions or interference caused by electrical appliances such as Mains Inverters Wireless Routers Cordless Phones Computers TVs and other electronic devices may reduce radio range performance While such occurrences are unusual they are possible In this case it may be necessary to either increase the physical separation between the Ness receiver and o...

Страница 3: ...Operation 20 Auto Time Automation 21 Auxiliary Outputs Manual Operation 22 Operation by SMS Messaging 23 Summary of SMS Commands 24 Programming by Navigator Keypad Programming Options Table 25 How to enter program mode 26 Set Brightness Set Volume 27 Setting the Real Time Clock 28 User Codes Programming 29 Radio Keys Programming 30 Timer Programming Entry Exit Delays 31 SMS Telephone Numbers 32 Pr...

Страница 4: ...to arm and disarm your system tells you what the system is doing you can use it to program alarm system and if that s not enough Navigator just looks great Navigator Touch Screen Keypad is compatible with Ness D8x and D16x control panels Version 7 and later D8XCEL D16XCEL 4G panels Rev 11 1 and later require Navigator keypad Rev 3 2 and later 1 Touch to arm the system 2 Touch to arm Home Mode 3 To...

Страница 5: ...spect Hwy Seven Hills NSW 2147 Australia nesscorporation com Info Screen See page 6 Your installer s contact details are stored here Never lose a business card again John Able Sydney Australia 02 8825 9222 sales ness com au Friendly Alarms Pty Ltd Ness Corporation contact details ...

Страница 6: ...leaning The Touch Screen Do not clean the touch screen with abrasive cleaners While the system is disarmed press Info Clean Screen to see the cleaning instructions Care Cleaning Step 1 In the disarmed mode press Info Step 2 Press Clean Screen Step 3 Press Start You have 10 seconds left Step 4 The touch screen will be disabled for 10 seconds Clean the bare screen or the protective film using a soft...

Страница 7: ...ask BEFORE application Step 1 Use the orange No 1 tab to peel off the self adhesive backing Step 2 Flip the film over to position the green No 2 tab at the top left Step 3 Holding the protective film by the green tab carefully apply the film to the Navigator s screen Start applying at one end and smooth the film as you go to remove any air bubbles Step 4 Use the green tab to peel off and discard t...

Страница 8: ...nd description of all zones Unsealed zones show a red indicator The Zone Status Bar displays the zone numbers of unsealed zones If only one zone is unsealed its description will also be displayed Zones which are currently in the alarmed state are displayed in flashing red text Touch the Zone Status Bar to display the full zone list Touch X to close the window ...

Страница 9: ... to adjust the Hours setting for Daylight Savings The date and time can be set in User Program Mode see page 28 If there is a System Alarm this area will display the alarm See pages 10 11 The cellular network signal strength is displayed here Signal strength range is 00 no signal to 30 Best signal Signal strength below 5 means the antenna should be checked or moved to a better reception area Signa...

Страница 10: ...se replace radio key battery Radio Low Battery System Alarm Display To display System Alarm details Touch the system alarm area If there is a System Alarm the clock area will display the alarm Touch to display details Touch to close the window Outstanding System Alarms shown here Full description of the System Alarm and what action to take Touch Next to view any other System Alarms Radio Key low b...

Страница 11: ...ow Radio Tamper alarm indicates that a device such as a Radio Reed Switch or Radio PIR may have been opened Check the device Radio Supervision if enabled by your installer alerts you if a radio device has not transmitted a signal for a set interval Ask your installer to check the radio device External Tamper alarm and Panel Tamper alarms Check the external siren cover and main panel ...

Страница 12: ... to indicate that those zones have been automatically excluded You should disarm the panel check the premises and then arm again Continual warnings could mean there is a problem with a detection device you will have to manually exclude the zone before attempting to arm the system If a zone is unsealed at the end of exit time and the auto exclude option is disabled the siren will sound for the dura...

Страница 13: ... User codes can optionally be programmed to be Arm Only codes An Arm Only code can arm the system but it cannot disarm However if an Arm Only code is assigned to a radio key the radio key OFF button will arm and disarm 1 If Entry Beeps are enabled 2 The strobe light will flash to indicate arming and disarming by radio key Your installer can also enable siren Chirps for an audible indication of rad...

Страница 14: ... the AUX button RK4 radio key only These options must be enabled by your installer Note Home Mode and Area arming Home Mode can be used if the panel is fully disarmed or if only Area2 is armed Home Mode is not available when Area 1 is armed The panel can be armed in Home mode if Area2 is already armed on these conditions Area 1 must be OFF Area 2 must be armed first and then Home Mode armed not th...

Страница 15: ...ally not enabled To enable this function consult your installer DURESS alarms can only used by systems which are monitored by a Central Station The DURESS alarm can be programmed to sound the internal siren Reset output This option is Off by default To trigger the keypad Duress Alarm add a special digit before your user code when disarming Touch A valid user code You can precede your user code wit...

Страница 16: ...al Station The Emergency Alarm display will show Medical and Fire alarms only if they have been enabled by your installer The Medical alarm sends a medical alarm report by dialler if this option has been enabled by your installer and the system is monitored by a central station The Medical Alarm does not sound the sirens The Fire alarm sounds the siren using the Fire Alarm sound and sends a Fire A...

Страница 17: ...uded so that it does not generate alarms When zones have been Excluded the EXCLUDE light flashes continuously while the panel is disarmed and also when armed Zones can be excluded while the panel is either disarmed or armed See notes below Zone Exclude is not permanent Excluded zones are automatically included next time the panel is disarmed Flashing Flashing In both disarmed and armed modes the Z...

Страница 18: ...ton flashes continuously when an alarm has occurred as a reminder to view the alarm memory Touching the MEMORY button to view the event history also clears the flashing memory alert The Event Memory window will close automatically when the last event has been viewed Event Memory To view the Event memory Touch Press Next to view the event memory from most recent to oldest There is no need to refer ...

Страница 19: ... beep the keypad or briefly sound the siren s or flash the strobe light or to sound an optional buzzer Typical Applications Day Zones are useful for a variety of applications such as a shop door beeper triggered by a reed switch on the door For example in a shop situation you can use Day Mode to alert you when a customer enters the front door You can also use Temporary Day Zones to monitor switche...

Страница 20: ...l disarmed mode This enables disables both Temporary and Permanent Day Zones When Day Mode is enabled any unsealed day zone will sound the programmed output for 2 seconds When Day Mode is disabled an unsealed day zone will simply be indicated on the keypad as an unsealed zone To disable Day Mode Touch ...

Страница 21: ...s prior to the AutoTime event Press any key on the keypad to stop the beeps during the warning period The beeps will start again for the final minute at a faster rate Final Minute beeps In the last minute prior to the Auto Time event the keypad will beep at a faster rate to warn that the event is about to start To Delay The Auto Time Event Optional function must be enabled by your installer To del...

Страница 22: ...AUX outputs which have been programmed for keypad control by your installer Touch a button to Pulse on or toggle an output Pulse or toggle is programmed by your installer Note Aux Outouts 5 8 are available if the optional Output Expander is fitted Manual Operation and Auto Time Schedules Manual operation of outputs works in conjunction with AutoTime schedules if programmed For example if AutoTime ...

Страница 23: ...K is the panel saying I have received the command and applied it NAK Not Acknowledged The NAK response indicates that the command was not accepted by the panel Check the format of your SMS or perhaps the command should have been sent in Installer program mode SMS ResponseS SMS is received from a known phone number one of the phone numbers programmed at P180E P189E a The panel will respond to any S...

Страница 24: ...lus zones and outputs status as per arming response above EXCLUDE zones Example zones 4 5 X123E4E5E X123E ACK 4E ACK 5E ACK E ACK zones excluded ZONE 4 ZONE 5 FIRE alarm1 Triggers the Fire Alarm if enabled F123E F123E ACK MEDICAL alarm2 Triggers Medical Alarm if enabled D123E D123E ACK PANIC alarm3 Triggers Panic Alarm if enabled S123E S123E ACK Operate AUX outputs eg Aux1 if enabled for use Aux2 ...

Страница 25: ...ur numbers Ph No 1 for SMS alarm reports programming P180E Ph No 2 for SMS alarm reports programming P181E Ph No 3 for SMS alarm reports programming P182E Ph No 4 for SMS Area 1 Open Close reports only P183E Ph No 5 for SMS Area 2 Open Close reports only P184E Ph No 6 for for SMS operation P185E Ph No 7 for for SMS operation P186E Ph No 8 for for SMS operation P187E Ph No 9 for for SMS operation P...

Страница 26: ...a new code of your own choice See page 29 Timers You can also re program the Entry Delay Time and Exit Delay Time if you need more or less time to exit and enter the premises See page 31 Telephone Numbers D8XCEL D16XCEL have 5 user programmable phone numbers for reporting of alarm events by SMS messaging See page 32 Enter program mode when the panel is in the normal disarmed mode To enter User Pro...

Страница 27: ...eferred Set Volume Adjust the beep volume of the Navigator touch screen Default All Config Items This option deletes your custom settings and returns all configuration options to factory default settings Slide your finger along the Brightness slider to adjust the brightness from 1 to 100 Slide your finger along the Volume slider to adjust the beep volume from 1 to 100 The volume cannot be set to z...

Страница 28: ...n allows you to program Day Of Month 01 31 Month 01 12 Year 10 63 Hour 00 23 24hr time format Minute 00 59 The Day Of Week is automatically calculated from the date and does not need to be programmed Date Format The date is entered in 24 hour format but is displayed on screen in 12 hour format In User Program Mode Touch To program Touch Touch Touch Touch Touch EXAMPLE To set the minutes Touch Ente...

Страница 29: ...s an alternative method for disabling user codes Note 2 All codes must be unique to each other Codes are rejected if already used Some codes that are similar to existing codes may also be rejected Touch to delete a user code The new user code will be displayed Up to 56 Keypad Codes can be programmed to control your XCEL panel Keypad Codes can be 3 to 6 digits in length User Code 1 is also the Mast...

Страница 30: ...o be used for arming and disarming of the panel The optional Ness Radio Interface is required for radio operation Ask your installer Indicates that this code has been enabled as a Radio Code If the option has been enabled by your installer Touch The display will show Press the disarm button on your Ness Radio Key or the No 1 button The green status bar will indicate that the Radio Key was successf...

Страница 31: ... Entry Delay Time 2 is internally multiplied by 10 For example enter 12 to get a time of 120 seconds Exit Delay Time 01 99 sec Exit Delay Time sets the time allowed to exit the premises after arming All zones except 24hr zones are inactive during the Exit Delay Time In User Program Mode Touch To program Touch Touch Touch EXAMPLE To set Entry Delay Time 1 Touch Enter the new delay 01 99 01 99 01 99...

Страница 32: ...n and programming commands These numbers do not receive any SMS alarm reports Note 1 Phone numbers 6 to 10 are not essential if the phone sending SMS commands is programmed in one of Phone Numbers 1 to 5 Note 2 The panel will respond to a valid command from any mobile phone number not just the numbers programmed However Unknown phone numbers will not get replies to invalid messages If open close r...

Страница 33: ...SMS REPLY P123E P26E 15E Entry Delay can be programmed in User Program Mode so the installer code is not required M123E ACK M26E ACK 15E ACK ME ACK This string of commands breaks down into easy to understand parts where P123E P26E 15E Enters user program mode 123 in this case is the Master code The option number for Entry Delay Programs Entry Delay to be 15 seconds Example 2 Program User Code 2 to...

Страница 34: ...med LOCATION and the zone name by the text ZONE 3 See the table page 35 To rename LOCATION and ZONE 3 SMS Sent to the panel SMS REPLY T123E LCN MYHOME Z3 Z3 RUMPUS text report changes made LOCATION MYHOME ZONE 3 Z3 RUMPUS 1 1 SMS alarm reports will then appear as NESS security report from MYHOME ALARM Z3 RUMPUS AREA 1 Tue 7 Aug 2018 4 07 22pm 1 1 Using the same method every word and phrase in the ...

Страница 35: ...rtcut NAME Navigator Installer Information Screen Your data INSTALLER NAME 1 IN1 Name INSTALLER COMPANY 1 IC1 Company INSTALLER ADDRESS 1 IA1 Address Line 1 INSTALLER ADDRESS 3 IA3 Address Line 2 INSTALLER TEL NO 1 IT1 Phone INSTALLER MOBILE 1 IM1 Mobile INSTALLER EMAIL 1 IE1 Email Default NAME Shortcut NAME RENAME ZONE 1 Z1 ZONE 2 Z2 ZONE 3 Z3 ZONE 4 Z4 ZONE 5 Z5 ZONE 6 Z6 ZONE 7 Z7 ZONE 8 Z8 ZON...

Страница 36: ...can include information about the zone or zones which caused the alarm tamper alarms low battery or mains failure reports and it can also by user number identify the users who arm and disarm the system Central station monitoring is highly recommended and is the most effective method of monitoring your alarm system For further information about 24 hour monitoring contact your installer or Ness Corp...

Страница 37: ...Manual for details ALARM Tells us there has been an alarm Z3 RUMPUS What caused the alarm In this case Zone 3 which has been renamed RUMPUS The zone name can be programmed by SMS otherwise the panel just reports the zone number see the Installer Manual for details AREA 1 Identifies the zone as belonging to Area 1 Tue 7 Aug 2018 4 07 22pm Time and date of the event 1 1 Means message 1 of 1 Long SMS...

Страница 38: ...on view the Alarm memory otherwise the icon will clear next time you arm the panel Cannot enter Program Mode The panel is armed Or you may be attempting to enter program mode using one of the user codes Disarm the panel before attempting to enter Program Mode Try again using the Master Code When I arm by radio key the keypad does not show ARMED immediately The panel is waiting 5 seconds for a seco...

Страница 39: ...29e SIrEN rESET TIME User code User code User code oPtion no oPtion no oPtion no Extra Options Assigned E g radio Code arm only etc Extra Options Assigned E g radio Code arm only etc Extra Options Assigned E g radio Code arm only etc 12 03 9 p201E p220E p239E Master Code 22 14 0 p202E p221E p240E 32 24 1 p203E p222E p241E 42 34 2 p204E p223E p242E 52 44 3 p205E p224E p243E 62 54 4 p206E p225E p244...

Страница 40: ...e Please activate the Ness SIM to enjoy the advantages of remote access and monitoring via the cellular network 2 Ness SIM benefits A Ness SIM card is supplied Easy online activation simple billing Competitive Retail Trade SIM plans No lock in contracts opt out anytime 1 Standard sized SIM required 2 Monthly network access charges apply once activated Access charges do not include central station ...

Отзывы: