12
to arm the system.
Touch
+
or touch
+
+
To arm
The control panel must be armed
in order to detect intruders.
Before arming, make sure all zones
are “sealed” by ensuring there is
no movement in rooms covered by
motion detectors and that doors
or windows protected by reed
switches are closed. The display
will tell you when the system is
ready for arming.
siren Warning
at the end of the exit time, all
zones should be sealed. If any are
unsealed, the siren will sound for
2 seconds to indicate that those
zones have been automatically
excluded. you should disarm
the panel, check the premises
and then arm again. Continual
warnings could mean there is a
problem with a detection device -
you will have to manually exclude
the zone before attempting to arm
the system.
If a zone is unsealed at the end
of exit time and the auto-exclude
option is disabled, the siren will
sound for the duration of siren
time, (the default is 5 minutes).
10
10 beeps on arming
means mains power may be turned
off or the backup battery is low.
one long beep when
you arm could mean the panel is
already armed or the keypad code
is wrong, (if not using Shortcut
arming).
A valid user code.