![Ness D16x Deluxe Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/ness/d16x-deluxe/d16x-deluxe_user-manual_1669334025.webp)
NESS D8X / D16X DELUXE CONTROL PANEL – USER'S MANUAL
25
The Ness D8x and Ness D16x control panels
have an on-board digital dialler which can send
detailed alarm messages to a Central Monitoring
Station.
The digital messages can include information
tamper alarms, low battery or mains failure
reports, and it can also (by user number) identify
MONITORING
the users who arm and disarm the system.
Central station monitoring is highly recommended
and is the most effective method of monitoring
your alarm system.
For further information about 24 hour monitoring,
contact your installer or Ness Corporation.
AUDIBLE VOICE MONITORING - ENHANCED
D8x/D16x version 8.0 and later has exhanced audible monitoring features using an onboard library of voice
messages to deliver clear and concise spoken word alarm messages to the recipient's mobile phone or landline.
Audible messages are detailed and interactive, with spoken word messages clearly stating the alarm condition
being reported. The user can then acknowledge the alarm and hang up or enter a remote control menu which
ALARM MESSAGE TRANSMISSION
Alarm reports are sent to the Primary (P70E) and Secondary (P71E) telephone numbers or only to the Follow Me
phone number (P00E) if programmed.
ALARM MESSAGE FORMAT
The alarm message starts with the introduction:
This is a security system message. To start the report press 1.
The recipient must press 1 on their phone. If not, the message repeats.
[System Name] security system reports the following
System Name is programmed by option P198E
[Alarm or Message] (See the Voice Messages table)
Wait to hear the report again, or to continue, press 1.
Press 1 on your phone. More alarm reports, if any, are heard.
Once all alarms have been acknowledged.
End of messages. To control the security system press 2 then, after the tone press 2 again. To acknowledge
and end, press STAR then press HASH and then hang up the phone.
Press STAR then HASH to hang up.
Press 2 then 2 to continue to the telephone remote control menu.
CENTRAL STATION MONITORING
www.msealarms.com.au