Power On after Power Failure Option
This option defines the behavior of POC-100 when DC power is supplied.
Value
Description
OFF
System is kept in off state when DC power is supplied.
Last State
The on/off state of the system is determined according to the last state when
DC power is disconnected. For example, if system is still on but DC power is
unplugged, the system is powered on next time when DC power is supplied.
ON
System is powered on when DC power is supplied.
When you want to use the AT-mode remote on/off control function, you have to set this
option to “ON”. Please refer to section 3.6 for instructions of using AT-mode remote on/off
control function.
To set “Power On after Power Failure” option:
1. When POC-100 boots up, press F2 to enter BIOS setup utility.
2. Go to [Advanced].
3. Set the [Power On after Power Failure] to a proper value for your POC-100.
Wake-on-LAN Option
Wake-on-LAN (WOL) is a mechanism which allows you to turn on your POC-100 via
Ethernet connection. To utilize Wake-on-LAN function, you have to enable this option first in