7. When the latched switch is closed, the DC power is break off and system is turn off.
When the latched switch is opened, the DC power is feed-in, and, with the correct
setting of “Power On after Power Failure” BIOS option, the system is turn on.
To power on POC-100 using an external non-latched switch
(ATX-mode)
For an application which places POC-100 inside a cabinet, it’s useful to control the on/off of
the system using an external switch. POC-100 provides an on-board 3-pin wafer connector
(for detail, please refer to section 2.3) for connecting a latched/non-latched switch and
behaves either AT-mode or ATX-mode power on/off control.
When using the ATX-mode on/off control, you need a non-latch switch. The external
non-latched switch acts exactly the same as the power button on the front panel. To power
on POC-100 using an external non-latched switch (ATX-mode), please follow the steps
listed below.
1. Prepare a non-latched switch with a 2-pin, 2.0mm pitch connector.
2. Connect the non-latched switch to the pin#9 and pin#10 of the on-board 2x8 pins,
2.0mm pitch box header (polarity is negligible).