POC-100 User’s Manual
Copyright © 2013 Neousys Technology Inc. All Right Reserved.
Page 47 of 65
When using the AT-mode on/off control, you need a latched switch. The external latched
switch controls the feed-in of DC power. When the switch is closed, the DC power is
break-off. When it’s opened, the DC power is feed-in. To power on POC-100 using an
external latched switch (AT-mode), please follow the steps listed below.
1. When POC-100 boots up, press F2 to enter BIOS setup utility.
2. Enter the [Power] menu.
3. Configure the [Power On after Power Failure] option as [ON]. This setting allows the
system to turn on after external DC power is feed-in. Please refer to section 4.1 for the
instruction of configuring this option.
4. Prepare a latched switch with a 2-pin, 2.0mm pitch connector.
5. Connect the latched switch to the pin#9 and pin#10 of the on-board 2x8 pins, 2.0mm
pitch box header (polarity is negligible).
6. You also need to configure the on/off mode configuration jumper to AT mode.