POC-300 Series
88
4.6
Power On after Power Failure
This option defines the system
’s behavior when DC power is supplied.
Value
Description
S0
– Power On
System is powered on when DC power is supplied.
S5
– Power Off
System is kept in off state when DC power is supplied.
Last State
Last system operating state when DC power loss occurred.
When you want to use the AT-mode remote on/off control function, you have to set
this option to “S0 – Power On”. Please refer to
section 3.7.2
for instructions of using
AT-mode remote on/off control function.
To set “Power On after Power Failure” option:
1.
Press
F2
when the system boots up to enter the BIOS setup utility.
2.
Go to
[Power]
.
3.
Set the
[Power On after Power Failure]
option to the desired setting.
4.
Once set, press
F10
to save setting and exit.
Содержание POC-300
Страница 1: ...Neousys Technology Inc POC 300 Series User Manual Revision 1 0 ...
Страница 4: ...Table of Contents 4 StopDICOS 108 DI COS Example 108 ...
Страница 20: ...POC 300 Series 20 1 5 Dimension 1 5 1 Superior View NOTE All measurements are in millimeters mm ...
Страница 21: ...POC 300 Series 21 1 5 2 Front Panel View NOTE All measurements are in millimeters mm ...
Страница 22: ...POC 300 Series 22 1 5 3 Bottom View NOTE All measurements are in millimeters mm ...
Страница 24: ...POC 300 Series 24 1 6 2 Wall Mount Bracket WM 300V NOTE All measurements are in millimeters mm ...
Страница 25: ...POC 300 Series 25 1 6 3 Wall Mount Bracket WM 300H NOTE All measurements are in millimeters mm ...
Страница 58: ...POC 300 Series 58 5 Reinstall the system enclosure ...
Страница 110: ...POC 300 Series 110 printf StopDICOS PASSED n printf npress any key to exit n system pause nul return 0 ...