OOO Neomatica. Terminal ADM007 GLONASS / GPS. Rev.1.3 dated 13.09.2019
17
If it is necessary to record a certain voltage level, for example, in the ignition switching circuit,
the voltage levels of the logical "
0
" with the
"INFALSE"
command and the logical "
1
" with the
"INTRUE"
command must be set for the selected analog input.
Description of the commands:
INFALSE IN, X0, Y0
IN - number of the analog input (always specify 0)
X0 - the lower limit of the logical range "0" (fixed value 0mV)
Y0 - upper limit of the logical range "0" (variable value)
INTRUE IN, X1, Y1
IN - number of the analog input (always specify 0)
X1 - the lower limit of the logical range "1" (variable value)
Y1 - the upper limit of the logical range "1" (fixed value of 60000 mV)
When entering these commands, the voltage must be specified in millivolts.
Figure 7 - Bands of discrete states
If the voltage level is in the zone of indifference, the previous discrete state is maintained until
the level goes beyond the zone of indifference.
The measured voltage levels are registered by the tracker and transmitted to the server.
When changing the discrete state, an extraordinary packet is sent.