30
4.5.2 Auto Nozzle Change
The auto nozzle change device is located at the left front of the machine
operator's console, as shown in the picture below.
The auto nozzle change settings page, as shown below.
1. The head can be fitted with two nozzles at the same time and the nozzle station can
also accommodate two nozzles, so it can support four different nozzle types at the
same time in an uninterrupted placement process.
2. The information to be entered on the nozzle replacement setting page are: the
nozzle to be replaced before which component, which placement head nozzle to be
replaced, where to put the original nozzle at nozzle station, which nozzle to be taken
from nozzle station.
3. Caution! When setting where to put the original nozzle to the nozzle station, you
need to ensure that the nozzle station position is vacant to avoid collision damage to
the nozzle and placement head.
4. If during mounting process, nozzle replacement action more than once, then after
Содержание YY1