8
4.3 Status of Indicators
There’s tri-color light on top of the cover, it is used to indicate whether all zones’
temperature have reached the well-set temperature. When all temperature reach
to well-set temperature, indicator light up green; While in the heating-up status,
indicator will flash as yellow; Only when the oven be switched off (without flash)
or in any faulty (in flash status), it will show as red .
4.4 Operation instructions
♦ Power on
Switch the button to ON status, machine start up. Please check the emergency button,
air switch and RCD before power on the machine.
♦Rail width adjustment method
The green button above the red temperature measurement interface on the left in above
picture is narrow adjustment, the green button above the blue temperature
measurement interface on the right is widening adjustment (press and hold the green
button for 3 seconds and then it automatically enters the fast width adjustment mode,
within 3 seconds for precise adjustment)
Note: In case of abnormal rail width adjustment, please adjust the width manually
by adjusting the manual adjustment handle at the back of the equipment.
Setting Transport
speed setting
Set temperature
Real-time temperature
Real-time status
Real-time power
Zone power on/ off
Power on/ off
Emergency
Width Adjustment
Button
Manual Width
Adjustment handle