15
FG7B CONTROLLER
Mapping
TABLE 4:
How the numbers relate to the IO Card Inputs
INPUT
INPUT FUNCTION
NUMBER
Input 1
ZONE 1 ON/OFF
1
Input 2
ZONE 2 ON/OFF
2
Input 3
ZONE 1 HIGH/LOW VOLTAGE
4
Input 4
ZONE 2 HIGH/LOW VOLTAGE
8
Input 5
GLOBAL ON/OFF
16
Input 6
GLOBAL HIGH/LOW VOLTAGE
32
ADD
SEE NOTE 5
128
Input 7
Can only be utilized through application software
Input 8
Can only be utilized through application software
LOADING A MAPPING FILE
The mapping files can be loaded on the FG7 with a USB stick as descripted below or through the
web interface (see the FG7 web interface)
Requirements
:
Flash drive loaded with nemshell7BText1.sh and with folder NemText
Inside folder NemText place etoimapplus.txt and/or itoemap.txt (these two files should be made
in Notepad)
Procedure:
1)
Connect power to the FG7 unit.
2)
Place the flash drive in the USB connector of the FG7 unit ( make sure there is only one
nemshell on the flash drive)
3)
On the top of the screen go to PIN and enter installer pin
4)
Go to the system tab.
5)
Press firmware upgrade
6)
Press the PWR button on the FG7. Wait until the Nemtek logo has disappeared and the
screen has gone black.
7)
Press the PWR button on the FG7
8)
Wait until the Display has come back on then remove the Flash drive.
Please note that if failsafe is ticked the mapping files are disabled.
Содержание FG7B