Description
Default
Value
Minimum
Value
Maximum
Value
Units Zero state One state
Comments
F111 Preset-Enabled Lock Mode
0
0
1
disabled
enabled
Enable to allow preset selections
while locked.
F112 Loadbank Mode Enable
0
0
1
disabled
enabled
Enable to allow for supply of
weld current through a fixed
resistive load.
F113 Stud Feed Weld Success Enable
0
0
1
disabled
enabled
Enable to suppress stud feed
signal under all conditions other
than a successful weld.
F114 Calibration Factor
0
-200
+200
Offset adjustment factor for
calibrating the Nelweld
F115 KFL Mode Enable
0
0
1
disabled
enabled
Enable only when using a KFL
gun.
F116 Quick Pilot Arc Mode
1
0
1
disabled
enabled
Enable to fire main arc as soon
as pilot arc is established.