Nelweld Operations and Service Manual
- 37 -
4.6.17 Resetting Default Parameters
To reset all controllable functions, to default
conditions, select special function F44 and press
and hold the time minus key until system resets.
This function resets the preset setpoints, as well
as the user weld counter.
4.6.18 Diagnostic Mode Enable
To help determine the cause of a problem
welding, enable diagnostic mode using special
function F66. When this function is enabled, a
flashing indicator on the control panel allows the
user to see that an error occurred. This error can
then be examined by interrogating special
function F1. (See diagnostic codes in the
troubleshooting guide).
4.6.19 Quick Retry Enable
To truncate the gun lift time on a misfire, enable
special function F26. When this function is
disabled, the gun will lift for the entire weld time
even on a misfire.
Special function F26 is particularly useful
in Weld Though Deck applications in
which high weld time settings are
typically used. For this reason, special function
F26 is automatically enabled or disabled when
Weld Through Deck is enabled or disabled.
The
‘Quick Retry Enable’ state may still be
overridden after being automatically changed.
4.6.20 Loadbank Mode Enable
The Loadbank Mode Enable function provides a
means of supplying weld power through a
loadbank by bypassing some logical checks (such
as pilot arc voltage and contact latch states). This
is primarily used for the purpose of calibration
because the loadbank is a stable load. When this
function is enabled, the gun coil will not lift.
Enable this function by setting F112 to one.
Disable this function for normal welding by
setting its value to zero.
4.6.21 Stud Feed Weld Success Function
The ‘Stud Feed Weld Success Function’ allows
the stud feed control to give the stud feed signal
only after completing the weld cycle with the full
main current. When this function is disabled, the
signal will be given after every weld attempt.
When this function is enabled, the signal will be
given after every successful weld. Weld errors
such as pilot arc errors (E009 or E010) and shunt
errors (E012) can be flagged using this function.
Note: F25 (Feed Signal Air Trigger Enable) is
overridden by this function.
4.6.22 Calibration Factor
The Calibration Factor allows for offset
adjustment of the output current. For example,
the Nelweld may be set to deliver 500A, but it is
proven to deliver only 490A. The calibration
factor may be adjusted in the positive direction
until the Nelweld is proven to deliver exactly
500A.
4.6.23 KFL Mode Enable
In the default state (disabled, or zero), the gun
drive circuit is set to drive a handgun. When
enabled, the KFL mode boosts the gun drive
supply as needed by the KFL gun. Enable this
function only when using the KFL gun.
4.6.24 Quick Pilot Arc Mode
In the default state (disabled, or zero), the pilot
arc time duration is as set with special function
F4. When enabled (or one), main current begins
as soon as the pilot arc is established, thus
truncating the pilot arc time duration.
Содержание Nelweld 4000
Страница 58: ...Nelweld Operations and Service Manual 58 7 5 Declaration of Conformity...
Страница 59: ...Nelweld Operations and Service Manual 59 8 0 Diagrams and Parts Lists 8 1 Front Section Not shown...
Страница 61: ...Nelweld Operations and Service Manual 61 8 2 Base and Side Cabinet Section...
Страница 65: ...Nelweld Operations and Service Manual 65 8 4 Rear Cabinet Section...
Страница 67: ...Nelweld Operations and Service Manual 67 8 5 Wiring Diagram...