C-Series 1" & 1-1/4" WS1 Manual
Volume Regeneration Day
Capacity Time Option Override Result
1
AUTO
NORMAL
oFF
Reserve capacity automatically estimated.
Regeneration occurs when volume capacity falls below the reserve capacity at the next
Regen Set Time.
AUTO
NORMAL
Any Number Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when volume capacity falls below the reserve
capacity or the specified number of days between regenerations is reached.
Any Number
NORMAL
oFF
Reserve capacity
NOT
automatically estimated.
Regeneration occurs at the next Regen Set Time when volume capacity reaches 0.
oFF
NORMAL
Any Number Reserve capacity
NOT
automatically estimated.
Regeneration occurs at the next Regen Set Time when the specified number of days between
regenerations is reached.
Any Number
NORMAL
Any Number Reserve capacity
NOT
automatically estimated.
Regeneration occurs at the next Regen Set Time when volume capacity reaches 0 or the specified
number of days between regenerations is reached.
AUTO
On 0
oFF
Reserve capacity
NOT
automatically estimated.
Regeneration occurs immediately when volume capacity reaches 0. Time of regeneration will not
be allowed to be set because regeneration will always occur when volume capacity reaches 0.
Any Number
On 0
oFF
Reserve capacity
NOT
automatically estimated.
Regeneration occurs immediately when volume capacity reaches 0. Time of regeneration will not
be allowed to be set because regeneration will always occur when volume capacity reaches 0.
AUTO
NORMAL on 0
oFF
Reserve capacity automatically estimated.
Regeneration occurs when volume capacity falls below the reserve capacity at the next Regen Set
Time or regeneration occurs after 10 minutes of no water usage when volume capacity reaches 0.
AUTO
NORMAL on 0 Any Number Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when volume capacity falls below the reserve
capacity or the specified number of days between regenerations is reached or regeneration occurs
after 10 minutes of no water usage when volume capacity reaches 0.
Any Number NORMAL on 0 Any Number Reserve capacity
NOT
automatically estimated.
Regeneration occurs at the next Regen Set Time when the specified number of days between
regenerations is reached or regeneration occurs after 10 minutes of no water usage when volume
capacity reaches 0.
1 Reserve Capacity estimate is based on history of water usage. Reserve Capacity estimate is not available with
alternator systems or Twin Tank Valve.
Filters should only use shaded options
WS Controller - Setting Options Table