-8-
C-Series 1" & 1-1/4" WS1 Manual
WS Controller - Softener System Setup
STEP 1S
Press NEXT and
q
simultaneously
for 3 seconds. If
screen in
Step 2S
does not appear in 5 seconds the lock
on the valve is activated. To unlock press
q
,
NEXT
,
p
,
and
SET CLOCK
in sequence, then press
NEXT
and
q
simultaneously for 3 seconds.
STEP 2S
Choose Softening
using
q
or
p
.
Press
NEXT
to
go to
Step 3S
.
Press
REGEN
to exit Softener System Setup.
STEP 3S
Enter the ion
exchange
capacity in grains
of hardness as
calcium carbonate
for the system
based on test data using
q
or
p
.
Press
NEXT
to go to
Step 4S
.
Press
REGEN
to return to previous step.
STEP 4S
Enter the pounds
of salt per
regeneration using
q
or
p
.
Press
NEXT
to
go to
Step 5S
.
Press
REGEN
to return to previous step.
STEP 5S
Backwash: Select
“NORMAL” or
“LONGER” using
q
or
p
. See
Tables 2 or 3 for
backwash times.
Press
NEXT
to go to
Step 6S
.
Press
REGEN
to return to previous step.
STEP 6S
Set Gallons
Capacity using
q
or
p
:
• “AUTO” (reserve
capacity
automatically
estimated and gallons capacity automatically calculated
from grains capacity and water hardness);
• “oFF” (regeneration based on day override); or
• number of gallons (20 to 50,000).
See Setting Options Table for more detail.
Press
NEXT
to go to
Step 7S
.
Press
REGEN
to return to previous step.
STEP 7S
Set Refill option
using
q
or
p
:
• “PoST” to refill
the brine tank
after the final
rinse; or
• “PrE” to refill the brine tank two hours before the
regeneration time set.
Press
NEXT
to go to
Step 8S
.
Press
REGEN
to return to previous step.