background image

-5-

C-Series 1" & 1-1/4" WS1 Manual

System Setup

Table 5 

WS1 & WS1.25 Regenerating Filter 

 

 

Single Backwash 

Double Backwash

 

 

Normal  Longer  Normal  Longer

 

Backwash 

14 

16 

12

 

Regenerate 

60 

60 

60 

60 

 

2nd Backwash 

 

 

10 

12

 

Rinse 

10 

10 

 

Total

4

 

82 

86 

86 

94

Cycle Time In Minutes

Table 6 

WS1 & WS1.25 Non-Regenerating Filter 

 

 

Single Backwash 

Double Backwash

 

 

Normal  Longer  Normal  Longer

 

Backwash 

14 

16 

12

 

Rinse 

10 

 

2nd Backwash 

 

 

10 

12

 

2nd Rinse 

 

 

10 

 

Total 

22 

26 

32 

40

Cycle Time In Minutes

The control valve with a water meter can be set for 

Demand Initiated Regeneration (DIR) only, Time Clock 

operation only or DIR and Time Clock which ever comes 

first, depending upon what settings are selected for Day 

Override and Gallon Capacity.

5

 See Table 7.

If a control valve does not contain a meter, the valve can 

only act as a time clock, and day override should be set to 

any number and gallon capacity should be set to off.
For DIR Softeners, there are two options for setting the 

Gallons Capacity. The Gallons Capacity is automatically 

calculated if set to AUTO. Reserve Capacity is 

automatically estimated based on water usage if AUTO 

is used. The other option is to set the Gallons Capacity 

to a specific number. If a specific number is set, reserve 

capacity is zero, unless the value is manually set (i.e. the 

manufacturer intentionally sets the gallon capacity number 

below the calculated capacity of the system).
The WS1 & WS1.25 control valves can also be set to 

regenerate immediately or at the next regeneration time 

by changing the Regeneration Time Option. There are three 

choices for settings:
1.  “NORMAL” means regeneration will occur at the preset 

regeneration time.

2.  “on 0” means regeneration will occur when the gallons 

capacity reaches zero.

3.  “NORMAL” and “on 0” means the regeneration will 

occur at the preset regeneration time unless the gallons 

capacity reaches zero. If the gallons capacity reaches 

zero the regeneration will begin 10 minutes after no 

water usage.

4  

Total time does not include fill time, which is dependent upon the 

amount of fill needed. When in the fill mode the system is providing 

treated water.

5

  See Installer Display Settings Step 3i for explanations of Day Override 

and Gallon Capacity.

The user can initiate manual regeneration. The user has 

the option to request the manual regeneration at the 

delayed regeneration time or to have the regeneration 

occur immediately:
1.  Pressing and releasing the 

REGEN

 button. “Regen 

Today” will flash on the display and the regeneration 

will occur at the delayed regeneration time. The user 

can cancel the request by pressing and releasing the 

REGEN

 button. This method of manually initiating 

regeneration is not allowed when the system is set to 

“on 0”, i.e. to immediately regenerate when the gallon 

capacity reaches zero.

2.  Pressing and holding the 

REGEN

 button for 

approximately 3 seconds will immediately start the 

regeneration. The user cannot cancel this request, 

except by resetting the control by pressing 

NEXT

 and 

REGEN

 buttons simultaneously for 3 seconds.

A unique feature of this control valve is the ability to 

display actual water usage for the last 63 days. The 

values are initially stored as “----”. This means the value 

is unknown. As days pass values are stored as “0” for no 

flow or the actual number of gallons. The counting of the 

gallons starts at the regeneration time. If no regeneration 

time can be set (i.e. when the valve is set for immediate 

regeneration) the counting of gallons starts at 12 a.m. Day 

1 is yesterday, day 2 the day before yesterday, etc. As 

new values are added the oldest history disappears.
Another unique feature is that the valve automatically 

calculates a reserve capacity when set up as a softener 

with “Gallons

Содержание C Series

Страница 1: ...C SERIES WS Programming Guide 1 1 1 4 Control Valve WS Series Models...

Страница 2: ...tents Control Valve Function Cycles of Operation 3 4 System Set Up 5 6 Setting Options Table 7 Softener System Setup 8 9 Filter System Setup 9 10 Installer Displays Settings 11 User Displays Settings...

Страница 3: ...can be cut above to below the top of tank thread The distributor tube is held in place by an o ring seal and the control valve also has a bayonet lock feature for upper distributor baskets The AC ada...

Страница 4: ...es in Minutes WS1 WS1 25 Downflow Softener Grains Capacity lb NaCl 6000 to 3501 3500 to 2501 2500 to 1700 lbs NaCl cu ft resin2 Less than 7 5 7 5 to 12 More than 12 Backwash Normal 6 8 8 Regenerate 45...

Страница 5: ...n 0 means the regeneration will occur at the preset regeneration time unless the gallons capacity reaches zero If the gallons capacity reaches zero the regeneration will begin 10 minutes after no wate...

Страница 6: ...ber Any Number than estimated capacity Yes None Yes Yes Yes Any Number Off Capacity set to AUTO and the Regeneration Time Option set to Normal or Normal on 0 The actual reserve capacity is compared to...

Страница 7: ...cause regeneration will always occur when volume capacity reaches 0 Any Number On 0 oFF Reserve capacity NOT automatically estimated Regeneration occurs immediately when volume capacity reaches 0 Time...

Страница 8: ...per regeneration using q or p Press NEXT to go to Step 5S Press REGEN to return to previous step STEP 5S Backwash Select NORMAL or LONGER using q or p See Tables 2 or 3 for backwash times Press NEXT...

Страница 9: ...ied number of days between regenerations is reached which ever comes first or after 10 minutes of no water usage when the gallon capacity reaches 0 zero See Setting Options Table for more detail Press...

Страница 10: ...ackwashes 8 minutes each LONGER for one LONGER backwash 16 minutes or LONGER 2 for two LONGER backwashes 12 minutes each See Tables 5 and 6 for additional details Press NEXT to go to Step 5F Press REG...

Страница 11: ...using porq buttons This display will not be shown if on 0 is selected in the OEM Setup Press NEXT to exit Installer Display Settings Press REGEN to return to previous step To initiate a manual regener...

Страница 12: ...d water when the regeneration has been completed Manual Regeneration Sometimes there is a need to regenerate the system sooner than when the system calls for it usually referred to as manual regenerat...

Страница 13: ...If the word ERROR and a number are alternately flashing on the display contact the OEM for help This indicates that the valve was not able to function properly STEP 1D Press porq simultaneously for t...

Страница 14: ...Used Since Last Reset The total number of gallons used since last reset will be displayed This display will equal zero if a water meter is not installed Press the NEXT button to go to Step 9D Press R...

Страница 15: ...hows the total number of regenerations that have occurred since startup Press the NEXT button to go to Step 7VH Press REGEN to return to previous step STEP 4VH Gallons Total Used Since Start Up This d...

Страница 16: ...embly Not Shown CL3186 AC Adapter 120V 12V CL3186EU AC Adapter 220 240V 12V EU 1 CL3186UK AC Adapter 220 240V 12V UK CL3186 01 AC Adapter Cord Only When replacing the battery align positives and push...

Отзывы: