Installation
Before connecting the unit, check whether the local
connection conditions (type of gas) are compatible with
the unit’s setting. Observe any special conditions imposed
by local suppliers (utilities). The specifications of this
cooktop are stated on the data label located on the
bottom of the cooktop base.
an accessible location near the hotplate if the data
A duplicate data label is supplied for adhesion to
accessed when the hotplate is installed.
label on the base of the hotplate cannot be
Gas inlet
connection
520-530
min.50
490
850
+-
1
+-
1
880
45
490
27
min. 100
1
Pressure
test point.
130
Pressure
test point
80
min. 600
Natural gas
This installation must conform with the following:
• Manufacturer’s Installation instructions
• Local Gas Fitting Regulations
• Municipal Building Codes
• Local Electrical Regulations
• Any other statutory regulations
details. These built-in hobs are intended to be
inserted in a benchtop cutout.
the appliance.
Preparing to
install
Installation dimensions are shown in Fig.1
.
• S.A.A. Wiring Code
Statutory
requirements
Before you begin, turn off the gas and electricity supply.
min 30 / m
ax 60
6
•
Gas Installations Standard - AS 5601
Only
authorised personnel
should connect
Refer to the
Gas
Installation
s
Standard
for piping size
LPG