73
•
Switch on the burner and turn the control knob
towards the minimum flow position ;
•
remove the knob;
•
using a screwdriver, adjust the set screw Z until
the correct low flame is obtained;
•
refit the knob.
•
Unscrew the set screw
Z
to increase the gas flow,
or screw it in to reduce the flow.
•
The setting is correct when the low flame measures
no more than about
3
or
4
mm.
•
Make sure that the flame does not go out on a
rapid change from maximum to minimum flow
and vice versa.
Minimum flow of valved
cooking hob taps
Connecting to LPG
Use a pressure regulator and connect the cylinder in
compliance with current guidelines and standards.