CLEARSKY DPF (PG 1050 & PG1060) INSTALLATION MANUAL
22
System Startup
• When all cables are connected the DCP3 should show “DPF Detected”.
If not, see Troubleshooting section.
• Start APU and allow it to run without load for 5 minutes.
• Check DPF variables:
– Start at home screen (where date and time are displayed), press
ESC/RESET if needed
– Press MENU
– Use arrows to find “DPF Manager”
– Press MENU
– Use arrows to find “Variables”
– Press MENU
– Look for values
Exhaust P = 5–20mB,
Exhaust T = 70–130°C
– If values are not in these ranges then check connections to sensors.
• Start a filter regeneration cycle:
– Start at home screen (where date and time are displayed), press
ESC/RESET if needed
– Press MENU
– Use arrows to find “DPF Manager”
– Press MENU
– Use arrows to find “Start Regen”
– Press MENU
– APU will slow down as DPF system draws power from the generator for
the exhaust heater
– Check DPF variables as above, within 5 minutes the Exhaust T should
be more than 500°C and the Exhaust P should be higher than the
reading before starting the regen.
• Press APU ON/OFF, the APU will shut down after the regen is complete
(just a few minutes).
Step 16