9
CLEARSKY DPF (PG 1050 & PG1060) INSTALLATION MANUAL
Installing Pressure Sensor and Tube
• Install pressure tube by fishing it in from the top. (Refer to figure 16, item 1
and figure 17, item 2.)
• Align tube so it does not rub on APU frame or other parts.
• Tighten lower fitting to 22–28 ft-lb.
• Install Pressure Sensor assembly (figure 18, item 3) to the top of the
pressure tube and tighten to 22–28 ft-lb.
• Remove the plastic fastening connector clip (figure 18, item 4) from APU
frame and bolt the p-clamp into this hole as shown in figure 19. Tighten
to 8–10 ft-lb.
Step 8
Figure 16. Pressure tube.
Figure 15. Pressure tube orientation.
Figure 18. Pressure sensor.
Figure 19. Pressure sensor.
1
TOP
(VERTICAL)
BOTTOM
(ANGLED)
Figure 17. Pressure tube.
2
4
3