background image

2

© by NECTA VENDING SOLUTIONS SpA

0012 Colibrì

IN CASE OF FAILURE

In most cases, any technical problems are corrected by
small repair operations; however, before contacting the
manufacturer we recommend that this manual be read
carefully.
Should there be serious failures or malfunctions, then
contact the following:

NECTA VENDING SOLUTIONS SpA
Via Roma 24
24030 Valbrembo
Italy - Tel. +39 - 035606111

TRANSPORT AND STORAGE

To prevent any damage, special care should be taken
when loading or unloading the vending machine.
The machine can be lifted by a motor-driven or manual fork
lift truck, and the blades are to be placed underneath the
machine.

Do not:

- overturn the vending machine;

- drag the vending machine with ropes or similar;

- lift the vending machine by its sides;

- lift the vending machine with slings or ropes;

- shake or jolt the vending machine and its packing.

The machine should be stored in a dry room where the
temperature remains between 0° C and 40° C.
Using the original packing, no more than 2 machines can
be stacked one on top of the other and always kept upright
as indicated by the arrows on the packing.

INTRODUCTION

This technical documentation is part and parcel of the
vending machine and must always follow the machine
in case it is moved or ownership is transferred, so as
to permit consultation by different operators.

Before installing and using the machine, it is first neces-
sary to carefully read and understand the instructions
contained in this manual, as they offer important hints on
safe installation, use and maintenance.

This manual is divided into three sections.

The first section describes the loading and routine clean-
ing operations which are carried out in areas of the
machine accessible with simple use of the door key,
without using any other tools.
The second section contains the instructions for correct
installation and all information necessary for optimum use
of the machine.
The third section describes maintenance operations which
involve the use of tools to access potentially dangerous
areas.

The operations described in the second and third
sections must be carried out only by personnel who
have the specific knowledge of the machine function-
ing from a point of view of electrical safety and health
regulations.

IDENTIFICATION OF THE VENDING
MACHINE AND ITS CHARACTERISTICS

Every machine is identified by its own serial number,
indicated on the data plate attached to the cabinet on the
right-hand side.
This plate (see Figure below) is the only one acknowl-
edged by the manufacturer and indicates all of the data
which readily and safely gives technical information sup-
plied by the manufacturer. It also assists in spare parts
management.

Water mains characteristics

Absorbed power

Operating voltage

Model

Product code

Boiler data

Current

Frequency

Serial number

Type

Содержание Colibri

Страница 1: ...INSTALLATION USE MAINTENANCE DOC NO H 155U 01 EDITION 2 00 12 UK English Page 1 Colibr Espresso Instant...

Страница 2: ......

Страница 3: ...a de identificaci n resulta conforme a las disposiciones legislativas de las directivas 89 392 89 336 73 23 CEE y modificaciones y integraciones sucesivas Declara que o distribuidor descrita na chapa...

Страница 4: ......

Страница 5: ...AND ADJUSTING THE MACHINE SETTINGS PAGE 14 STANDARD SETTINGS PAGE 14 ADJUSTING THE COFFEE UNIT PISTON STROKE SETTING PAGE 14 WATER TEMPERATURE CONTROL PAGE 14 ADJUSTING THE GRADE OF GRINDING PAGE 15 A...

Страница 6: ...different operators Before installing and using the machine it is first neces sary to carefully read and understand the instructions contained in this manual as they offer important hints on safe inst...

Страница 7: ...achine on a cabinet The machine can be installed on a table or on any other suitable stand recommended height is 820 mm If possible it is advisable to use the special cabinet which can house the liqui...

Страница 8: ...e installed in the support cabinet optional AVAILABLE ADJUSTMENTS Grade of grinding for espresso coffee coffee and water doses by volume time adjustment for instant products Temperature control Factor...

Страница 9: ...power consumption depends on many fac tors such as the temperature and ventilation of the room where it is installed the inlet water and boiler temperature etc The above power consumption calculated f...

Страница 10: ...idator 8 Prearrangement for cashless payment systems MAINTENANCE AND DISINFECTION According to current safety rules and health regulations the operator of an automatic vending machine is respon sible...

Страница 11: ...aper strip ensuring that the stirrers are all placed horizontally Replace the stirrer weight The stirrers must be burr free and not curved LOADING CUPS To load cups do as follows open the door slightl...

Страница 12: ...ared chlorine based detergent reinstall the feeders and the water funnels reinstall the powder deposit drawers and the powder funnels after thoroughly drying them After reinstalling all parts the foll...

Страница 13: ...mptying and cleaning The coffee container capacity is greater than that of the waste container if the support cabinet is not used Themachinecontrolsoftwareindicatesonthedisplay that themaximumnumberof...

Страница 14: ...illed or at least once a week any powderresidueshouldberemovedfromtheexternalparts of the coffee unit particularly from the coffee funnel area see Fig 17 SUSPENDING FROM USE If for any reason the mach...

Страница 15: ...Fig 9 CONNECTING THE MACHINE TO THE WATER MAINS The machine must be connected to the drinking water mains taking into account law provisions in force in the country where the machine is installed The...

Страница 16: ...de the machine the only energised parts are the ones which are covered with protective cas ings which are marked with a plate indicating before removing the cover disconnect the electricity Before rem...

Страница 17: ...xample during maintenance it is pos sible that an installation cycle is automatically started when the machine is switched on Versions with internal tank For models with an internal tank when the mach...

Страница 18: ...spring 6 Swinging lever STANDARD SETTINGS The vending machine is supplied with the following set tings coffee temperature at the spout approx 70 80 C instant product temperature at the spout approx 70...

Страница 19: ...re Installation Installation under way Sel not avail Selection disabled Coffee sel out For espresso models only Coffee unit out of service Take the drink Drink ready Fig 15 1 Coffee grinder 2 Grinding...

Страница 20: ...he menu with the and buttons to highlight the following functions Compl selec Dispensing test including cup sugar and stirrer Powd only Dispensing powder only Water only Dispensing water only No Acces...

Страница 21: ...ially if involving the use of a vehicle the hydraulic system must be emptied manually DISPLAYING THE STATISTICS Pressing button when the display indicates the Dis play statistics function causes the s...

Страница 22: ...he accessories to be dispensed with each single button Discount determining the price reduction for selections without cup Special sales setting free vend and jug facilities parameters Euro displaying...

Страница 23: ...cts power from the release motor and the machine locks LIQUID WASTE CONTAINER FULL If the machine is equipped with a liquid waste container housed in the cabinet fitted with an overflow warning device...

Страница 24: ...6 validator coin lines can be changed The value of the lines is expressed in number of basic coins Press the confirm button from the programming menu to access the list of lines which can be scrolled...

Страница 25: ...age is enabled or not ON OFF If the message is enabled when pressing the confirm button the first character will blink which can then be changed The buttons will be assigned the following functions 1...

Страница 26: ...will be reset PROGRAMMER OPTIONAL AUTOMATIC SETUP TRANSFER Usingtheprogrammerdevicemakesitpossibletoreadout the programming routines set and transferred to other apparatuses from a given vending mach...

Страница 27: ...unt Special sales Password for Free Vend Password for Jug facilities Number of selections for Jug facilities SETTING THE LANGUAGE It is possible to change the programmer configuration as concerns the...

Страница 28: ...elevant systems must be checked by qualified per sonnel at least once a year Switch the machine off before any maintenance op erations which require removal of components The following operations must...

Страница 29: ...rding to the use of the machine and the quality of the inlet water the entire foodstuff circuit system must be cleaned and sanitised in the following way all parts of the hydraulic system in contact w...

Страница 30: ...DC the green LED when blinking indicates that the micro processor is working correctly the red LED indicates the operating status of the boiler heating element Fig 19 1 230 V users 2 RAM 3 EPROM 4 Inp...

Страница 31: ...ties 5 To display board 6 Display contrast adjusting trimmer 7 Programming button 8 Cleaning button 9 RS232 port 10 To the programmer 11 Display board PUSH BUTTON BOARD This board controls the alphame...

Страница 32: ...by NECTA VENDING SOLUTIONS SpA 28 0012 Colibr HYDRAULIC SYSTEM 1 Water inlet solenoid valve 2 Air break 3 Volumetric counter 4 Vibration pump 5 Bypass 6 Boiler 7 Coffee unit Espresso Instant...

Страница 33: ...s Statistic N 1 Sel N 1 P xxxx Sel N 1 G xxxx Sel N 1 T xxxx Sel N 8 P xxxx Sel N 8 G xxxx Sel N 8 T xxxx Statistic N 2 Pr sel 1 XXXX Pr sel 8 XXXX Statistic N 4 FAILURE COUNTER LIST OF FAILURES N 1 A...

Страница 34: ...m with the printer connected print all statistics as displayed Delete data Confirm Working After a few seconds all data is reset with the exception of the general counter Counter Counter ON OFF CASHED...

Страница 35: ...ction 7 Sec Water only Selection 7 Sec No accessories Selection 7 Sec Dispensing Menu Dispensing Dispensing Dispensing TEST DISPENSING Special functions Key 2 1 Previous function 2 Grind and release a...

Страница 36: ...mechanism N 4 RAM data N 5 Water failure N 6 Cup failure N 7 Water leak N 8 Volumetric counter N 9 Coffee unit N 10 Coffee failure N 11 Coffee release N 12 Cup release N 13 Liquid waste full dC XXXX A...

Страница 37: ...TION 0 to 3 Previous price PRICE VALUE AND BUTTON STATUS Next price Set Prices Set Prices Button Button 1 ON Button 8 ON Button 1 ON Price N Basic unit PD Basic unit XXXX Dec point X Dec point Payment...

Страница 38: ...OR SETTING Payment system Validator Executive std Credit Basic unit PD Power supply 12 24 V Coin line value A to F Line A Credit Excess credit available Price holding ECS UKey Initialising Validat lin...

Страница 39: ...ment system Machine type C Espresso I Instant Tank Type of doses for Italy France Spain Great Britain Machine code Working List of layouts available per model country See selection dose table Water su...

Страница 40: ...A nnnn P nnnn A nnnn P nnn A nnnn After entering 4th digit confirm new value P Programmed number of selec tions A Number of selections made P nnn A nnnn X Cancel Confirm Reset counters of selections...

Страница 41: ...Display messages in available languages Italian French English Spanish Set Prices Whipping time Whipping d s XXX Whipping Selection Config Prom message Message xxxxxxxxxxxx To access programming Pass...

Страница 42: ...6 Confirm function confirm data item 7 Change data item 8 Reset failures SELECTION CONFIGURATION Password Selection Config Cup release ON Button 8 Button 1 Cup release Special sales ON Enable Disable...

Страница 43: ...N Euro Nat Nat Euro Disabled Special sales Discount Free Vend ON OFF Password XXXX Password XXXX ON Se OFF Se ON Jug Facilities ON Password XXXX Password XXXX Se OFF Remaining sel X Remaining sel X X...

Страница 44: ...V 24 V TX DELAYED FUSE X COURRENT VAR VARISTOR VENT FAN CODE DESCRIPTION BDV BDV COIN MECH CONNECTOR CM1 COFFEE UNIT MOTOR CAM CMSB CUP RELEASE MOTOR CAM CV VOLUMETRIC COUNTER E1 SOLENOID VALVE INSTAN...

Страница 45: ...by NECTA VENDING SOLUTIONS SpA NOTE...

Страница 46: ...NECTA VENDING SOLUTIONS SpA...

Страница 47: ...Colibr Espresso...

Страница 48: ...NECTA VENDING SOLUTIONS SpA...

Страница 49: ...Colibr Instant...

Страница 50: ...by NECTA VENDING SOLUTIONS SpA NOTE...

Страница 51: ...t any responsibility for any inaccuracies contained in this publication which can be ascribed to printing and or transcription errors All instructions drawings tables and information contained in this...

Страница 52: ......

Отзывы: