23
© by NECTA VENDING SOLUTIONS SpA
0404 211 - 02
TEST
SELECTIONS
This function is used to simulate the normal dispensing of
products without inserting any money.
Check the functioning of the motor rotation by pressing the
selection buttons.
MOTOR TEST
It activates all motors in a sequence.
AUTOTEST
A function to check, in a semiautomatic manner, the
correct operation of some devices is implemented in the
software.
Some checks occur automatically, others need the manual
operation of the monitored component; button “ ” is
pressed to go to the next check.
The monitored devices are:
“Keypad”
Press the button requested on the display; if it works
correctly the request for the next button is presented.
“Temperature”
The value of temperature detected by the probe is dis-
played.
In the event of disconnection the value -11.0 is displayed.
In the event of a short-circuit the value 41.0 is displayed.
Press “ ” to advance.
“Buzzer”
A series of sounds is emitted.
“Compressor”
The compressor is activated/deactivated using the “ ”
and “ ” buttons.
“Selections”
All selections are activated in a sequence.
“Coin mechanisms”
Checking that communication with the coin mechanism
takes place correctly and which validator lines are set as
being active.
“Photocells”
If the product detection device is present, the light beam
reading and interruption are checked.
“Disp compt lock”
If the device for locking the dispensing compartment
opening, use the “ ” and “ ” buttons to lock and unlock the
compartment opening.
“Direct keypad”
If fitted on the machine, the 5 buttons are checked
sequentially.
Press the button requested on the display; if it works
correctly the request for the next button is presented.
MACHINE INFORMATION
The machine can memorize a series of codes which will
identify it when retrieving statistics.
More specifically the following can be stored:
- 6-digit operator code;
- 8-digit vending machine code which identifies the
machine.
INSTALLATION DATE
This function is used to store the current date of system,
if set correctly, as installation date.
The date is printed when retrieving the statistics.
MACHINE CODE
When the “Machine code” function is displayed the eight-
digit numeric code identifying the machine can be changed
(from the default 0).
OPERATOR CODE
When the “Operator code” function is displayed the six-
digit numeric code identifying groups of machines can be
changed (from the default 0).
INITIALISING
When the “Initialise” function is displayed the vending
machine can be initialised, selecting the “country” (in-
tended as configuration type) and the language, restoring
all related default data.
This function should be used in the event of a memory data
error or when the software version is replaced/updated.
All statistic information will be reset.
Press confirm button “ ”; the country and the language to
be used are requested, then the message “Confirm?” is
displayed. Press confirm button “ ” a second time and the
message “Working” is displayed for a few seconds.
Содержание Sfera
Страница 1: ...INSTALLATION USE AND MAINTENANCE MANUAL UK English Sfera DOC NO H 211U 02 EDITION 2 2004 04...
Страница 2: ......
Страница 4: ......
Страница 62: ...sx38500...
Страница 63: ...Sfera...
Страница 64: ...sx38601...
Страница 65: ...Sfera...
Страница 66: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 68: ......