11
© by NECTA VENDING SOLUTIONS SpA
0404 211 - 02
MAIN SWITCH
The power supply unit (see Fig. 23) is fitted with a
microswitch that, when opening the sliding compartment,
disconnects the power from the machine electrical sys-
tem,
except from the terminal board supporting the line
cable, the line fuses and from the same switch area.
Before removing the cover from these parts (indicated
with a specific plate) it is necessary to disconnect the
external switch.
The power supply can be reconnected, if necessary, by
inserting the special key supplied with the machine.
All operations which require the machine to be ener-
gised with the door open must be carried out by
qualified personnel who are aware of the specific risks
of such condition.
DISPENSING COMPARTMENT
MANUAL RELEASE
Some models are fitted with a lock device in the dispens-
ing compartment that is released through electric control
when a selection is made (see compartment lock param-
eters).
Should for any reason be necessary to open the compart-
ment without electric power, do as follows:
- remove the last tray;
- remove the anti-theft grille;
- manually operate the lock device (see Fig. 27).
The cooling unit is located in the lower part of the cabinet.
When sliding sideway all the shutters on the cold air
distribution duct, lining up the duct holes with the ones on
the shutters (shutters in the open position), a uniform
temperature is obtained in the cabinet (setting between
5°C and 20°C).
With the ventilation grille partially covered by the shutters
in the closed position, the temperature in the cabinet is
diversified between the upper trays, with the correspond-
ing holes on the duct closed by the shutters (12-18°C), and
the lower trays, with the holes on the duct open (5 -8°C).
According to the number of shutters in the open or closed
position, it changes the level of temperature stratification
in the cabinet.
The cooling unit is defrosted automatically every 6 hours.
In any case, the timing is programmable.
The power supply unit, mounted in the lower section of the
cabinet, contains the relay card which activates the com-
pressor, the protection fuses and the switch on the pay-
ment system door.
Fig. 15
1 - Product dispensing compartment housing
2 - Cooling unit condenser
3 - Removable ventilation grille
4 - Cooling unit evaporator
5 - Cold air flow grilles
6 - Removable cold air flow shutters
7 - Tray guides
8 - Glass-front opening handle
9 - Removable payment system compartment
10 - CPU board
11 - Payment system compartment lock
12 - Compartment opening handle
13 - Coin mechanism support
14 - Product passage photocells
15 - Power supply unit
16 - Door switch
Содержание Sfera
Страница 1: ...INSTALLATION USE AND MAINTENANCE MANUAL UK English Sfera DOC NO H 211U 02 EDITION 2 2004 04...
Страница 2: ......
Страница 4: ......
Страница 62: ...sx38500...
Страница 63: ...Sfera...
Страница 64: ...sx38601...
Страница 65: ...Sfera...
Страница 66: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Страница 68: ......