![NEC Univerge UM8000 Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/nec/univerge-um8000/univerge-um8000_installation-manual_248355060.webp)
Issue No. 1.0
UM8000
8 - 4
Setting Up Integration (SV8300)
4.
Assign the phantom extension number to the UCD pilot (master) number.
5.
Assign all UCD numbers to UCD group number 00.
6.
Make busy the UCD pilot extension number.
7.
Assign the UCD pilot (master) number to the tenant number.
2.5
Enabling the Automated Attendant
To use the voice messaging system as an automated attendant, program the
phone system to send external calls to the UCD pilot (master) extension.
Command Code:
171
First Data:
xxx
Where <
xxx
> is the UCD pilot
extension number.
Second Data:
1
Command Code:
172
First Data:
xxx
Where <
xxx
> is the extension
number.
Second Data:
000
NOTE
Repeat this command for each voice messaging extension number and
for the UCD pilot (master) number.
Command Code:
E50
First Data:
xxx
Where <
xxx
> is the UCD pilot
extension number.
Second Data:
0
Command Code:
5115
First Data:
000
Second Data:
xxx
Where <
xxx
> is the UCD pilot
extension number.
Содержание Univerge UM8000
Страница 1: ...UM8000 Doc No 10569 Issue 1 0 Installation Manual ...
Страница 2: ......
Страница 4: ......
Страница 12: ...Issue No 1 0 UMJ8000 viii Table of Contents THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 24: ...Issue No 1 0 UM8000 2 6 WinSCP and PuTTY THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 30: ...Issue No 1 0 UM8000 3 6 The Web Administration Console Figure 3 4 UM8000 Integration Options ...
Страница 42: ...Issue No 1 0 UM8000 4 4 System Components THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 73: ...UM8000 Issue No 1 0 Installation Manual 9 5 Figure 9 4 UM8000 Integration Options ...
Страница 102: ...Issue No 1 0 UM8000 11 12 Remote Maintenance 6 You are now logged into the WAC Figure 11 7 Web Admin Console ...
Страница 128: ...Issue No 1 0 UM8000 14 6 Updating UM8000 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 129: ......