UNIVERGE SV8100
Issue 1.0
System Maintenance Manual
3 - 7
S
ECTION
6
C
OMMON
DIM C
OMMANDS
Enter
Function
DIM Output
Mail in 0000
Output of all system activity is
turned on.
No ISDN information output.
Enter CAPS debug mode.
The activity of all extensions and lines is
output.
Mail in 0000
Output of all system activity
is turned off.
Exit CAPS debug mode.
Enter
Function
DIM Output
Mail in 0012
Output of all ISDN activity on
the system is turned on.
Enter ISDN debug mode.
master current bid : xxH
master current line : xxH
The activity of all ISDN blades will be output.
Mail in 0012
Output of all ISDN activity on
the system is turned off.
Exit ISDN debug mode.
When the ISDN output is turned on, the DIM will output the ISDN blade slot and
circuit that is currently set as the master clock for the system.
The slot number is shown by master current bid : xxH (xx is the slot number in
hexadecimal).
The circuit of the blade is shown by master current line : xxH (xx is the circuit number
in hexadecimal).
Содержание Univerge SV8100
Страница 2: ......
Страница 3: ...System Maintenance Manual INT 2057 UNIV ISSUE 1 0...
Страница 4: ......
Страница 6: ......
Страница 8: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 18: ...Issue 1 0 UNIVERGE SV8100 1 6 Troubleshooting IP on an SV8100 System Figure 1 3 Trace File Example...
Страница 40: ...Issue 1 0 UNIVERGE SV8100 2 22 System Maintenance NOTES...
Страница 76: ...Issue 1 0 UNIVERGE SV8100 3 36 NOTES...
Страница 77: ......
Страница 78: ...System Maintenance Manual NEC Unified Solutions Inc Issue 1 0...