UNIVERGE SV8100
Issue 1.0
System Maintenance Manual
2 - 17
E3
No Dial Access to Features on SLT
Check to see if SLT can access
internal or CO dial tone.
Yes
Yes
Yes
No
No
No
Access dial
tone?
Go to Flowchart E1.
Check PRG 20-06 for
feature assignment.
Feature
allowed?
Program COS to allow
feature, and test.
Good
Bad
Done.
Check PRG 11-01 and
PRG 11-10~PRG 11-15 for
access assignment.
Correct
Access Code?
Recheck feature access with
correct Access Code.
Recheck SLT features operation
selection to verify procedure for
feature.