Содержание Univerge SV8100

Страница 1: ...rmat changes may occur When viewing and printing this document we cannot guarantee that your specific PC or printer will support all of the fonts or graphics Therefore when you view the document fonts...

Страница 2: ......

Страница 3: ...System Maintenance Manual INT 2057 UNIV ISSUE 1 0...

Страница 4: ......

Страница 5: ...s Inc and shall not be reproduced without prior written approval of NEC Unified Solutions Inc Dterm is a registered trademark of NEC Corporation UNIVERGE is a trademark of NEC Corporation Windows is a...

Страница 6: ......

Страница 7: ...System Maintenance The technician can use this chapter to troubleshoot and diagnose problems during and after SV8100 system installation The troubleshooting flow charts and general test procedures hel...

Страница 8: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 9: ...2 2 Pinging from an UNIVERGE SV8100 IP Phone 1 3 Section 3 Packet Traces 1 5 Chapter 2 System Maintenance Section 1 Introduction 2 1 Section 2 Operational Test Procedures 2 1 2 1 General Information...

Страница 10: ...of the CD CP00 US 3 2 Section 4 To Disconnect from the DIM Locally via the Ethernet Socket of the CD CP00 US 3 3 Section 5 SV8100 DIM Commands 3 4 Section 6 Common DIM Commands 3 7 Section 7 SV8100 N...

Страница 11: ...___________________ ___________________________________________________________________________________ LIST OF FIGURES Figure 1 1 Ping Traces 1 2 Figure 1 2 Ping Usage Example 1 4 Figure 1 3 Trace Fi...

Страница 12: ...___________________________________________________________ iv List of Figures ___________________________________________________________________________________ Issue 1 0 UNIVERGE SV8100 THIS PAGE I...

Страница 13: ...Microsoft Windows and is also implemented on the UNIVERGE SV8100 IP Phones Ping sends a small IP packet to a specified destination and waits for a response back It should be possible to ping IP Phones...

Страница 14: ...Issue 1 0 UNIVERGE SV8100 1 2 Troubleshooting IP on an SV8100 System Figure 1 1 Ping Traces Unsuccessful Ping Trace Successful Ping Trace...

Страница 15: ...at there are other options available with the Microsoft Windows implementation of ping The most commonly used options are listed above Examples P ping 192 168 2 100 t Continually pings 192 168 2 100 u...

Страница 16: ...hone 192 168 1 100 P Local Hub P Local Router 192 168 1 1 P Leased Line P Remote Router 192 168 2 1 P Remote Hub P UNIVERGE SV8100 You will see that by pinging from the System IP Phone and PCs we can...

Страница 17: ...acket trace utility also known as Sniffers to determine what data is being transmitted and received on an ethernet network These can be particularly useful to determine the cause of connection issues...

Страница 18: ...Issue 1 0 UNIVERGE SV8100 1 6 Troubleshooting IP on an SV8100 System Figure 1 3 Trace File Example...

Страница 19: ...mory fails this data on the disk can be uploaded and the memory restored SECTION 2 OPERATIONAL TEST PROCEDURES 2 1 General Information When an UNIVERGE SV8100 system is first powered up an initializat...

Страница 20: ...display shows default time and date indications For example 12 2 Fri 10 47 AM 2 4 After Initialization Check all blade slots in software to ensure the initialization process scanned the installed har...

Страница 21: ...icient steps to the solution can be taken Flowcharts in the next section help define the problem 3 2 1 System Down This term describes one of the following situations U No access to internal dial tone...

Страница 22: ...ll Dropping C2 2 9 4 No Outside Dial Tone Access C3 2 10 5 CO PBX Dialing Problem Cannot Dial Out on CO C4 2 11 C Multiline Terminal Problems 1 Multiline Terminal Function D1 2 12 2 Multiline Terminal...

Страница 23: ...eplace Corresponding Power Supply MPS7101 Fuses F1 and F2 good Turn system On Dial Tone on Multiline Terminal on 1st CD 8DLCA Dial Tone No Dial Tone Replace Fuse s Reset CD 8DLCA If trouble persists r...

Страница 24: ...tation Cabling Replace Corresponding Power Supply No Indication Terminal Installed Indication Yes Done Problem Solved No Replace chassis No Problem Solved Yes Correct Indication Reset CD 8DLCA If trou...

Страница 25: ...on CO Lines Yes Yes Yes No No No End End RFI Cleared RFI Cleared Inform Telco Twisted pair More than 1 pair Twisted Ground all unused pairs at MDF Cable with 1 pair twisted pair cable Follow the steps...

Страница 26: ...ing Chassis Replace CAT 5 cable between chassis Check whether or not affected lines can be isolated to one chassis Return defective Multiline Terminal for repair Reset Replace CD 4COTB 1 CD 4COTB Prog...

Страница 27: ...key after call drops CO Line Key LED Status Check CD 4COTB LED Have Telco check line circuits Increase Automatic Release Signal Detection Time Refer to PRG 14 02 09 CD 4COTB LED Status Off On Have Tel...

Страница 28: ...CD 8DLCA installed Go to Flowchart A1 All Terminals affected Check for Internal Dial tone Internal Dial Tone Go to Flowchart A1 Test for CO dial tone at MDF with test set and check CO wiring Have Tel...

Страница 29: ...heck CO lines at MDF with test set to see if they are DTMF or DP DP or DTMF DP or DTMF Program lines for DTMF Program lines for DP Program as DP Yes No Digits Sent Monitor Line with test set and verif...

Страница 30: ...rd 3 Press each terminal key to test tones LEDs and key contacts 4 Return terminal on line by taking handset off hook and then return to on hook Problem solved End Reset and test Replace defective ter...

Страница 31: ...ID Check and adjust volume control and test again Yes Yes Yes Yes Yes Yes No No No No No No Problem Solved Station in Call Forward or DID Cancel feature Wrong Assignment Program again Program again Do...

Страница 32: ...2 14 System Maintenance Multiline Terminal Dial Tone Access Problems D3 Check to see if problem occurs on CO or Internal call Go to Flowchart A1 Go to Flowchart C3 Go to Flowchart A1 CO Internal Both...

Страница 33: ...e Access on SLT E1 Check PRG 10 03 for CD 4LCA CD 8LCA assignments Assignment correct Assign Again End Replace SLT and test Replace SLT and test Both CO Internal Good Go to Flowchart C3 Go to Flowchar...

Страница 34: ...d Cancel call Forwarding Check CD 4LCA CD 8LCA for ring voltage output with AC meter Pass Fail Busy Idle Check BLF indication for station Replace CD 4LCA CD 8LCA RSG Test BLF Indication Busy Idle Term...

Страница 35: ...Yes No No No Access dial tone Go to Flowchart E1 Check PRG 20 06 for feature assignment Feature allowed Program COS to allow feature and test Good Bad Done Check PRG 11 01 and PRG 11 10 PRG 11 15 for...

Страница 36: ...Done Replace CD 4COTB Check line with dB meter and or contact Telco Report Problem to Telco Less than 8 dB Line Port Reset or replace CD 4COTB and test again All lines Bridge on system CO line Remove...

Страница 37: ...wiring removed External page heard on test set External amplifier or PRG 11 01 and PRG 11 10 PRG 11 15 Check PRG 11 01 and PRG 11 10 PRG 11 15 for correct access code external for paging Done Pass Fai...

Страница 38: ...0 System Maintenance H1 SMDR Output Problems No Call Accounting System Yes No Incoming problem only Check PRG 35 02 08 Is Output Type Set correctly Check PRG 35 01 01 TCP IP Set PRG 35 01 01 Correctly...

Страница 39: ...age Check PRG 35 01 03 and PRG 80 05 01 Set port correctly for Trunks and Dept Groups Check PRG 35 03 01and PRG 35 04 01 Include the call type Check PRG 35 01 05 07 PRG 35 02 01 03 Set Trunk to provid...

Страница 40: ...Issue 1 0 UNIVERGE SV8100 2 22 System Maintenance NOTES...

Страница 41: ...As well as monitoring the system the DIM can also be used to change the operation of the system For this reason DO NOT enter the following commands as they will cause a system restart R RESET R RESTAR...

Страница 42: ...is 192 168 0 10 Sub Net Mask 255 255 255 0 Using a terminal application e g Hyperterminal set the connection to TCP Winsock The Host IP address is set by Program 10 12 01 on the SV8100 The default is...

Страница 43: ...nnection to the DIM is made and system activity is observed Refer to Figure 3 2 SV8100 System Activity SECTION 4 TO DISCONNECT FROM THE DIM LOCALLY VIA THE ETHERNET SOCKET OF THE CD CP00 US Turn off a...

Страница 44: ...Result DATE Date Time RB Read 8bits RW Read 16bits RD Read 32bits WB Write 8bits WW Write 16bits WD Write 32bits DUMP Memory Dump FILL Memory Fill MEMSET Memory Fill MEMCPY Memory Copy MEMCMP Memory C...

Страница 45: ...SH3 control HELP This help display SYSDT System data OFFLINE OFFLINE OPMS OPMS info IP IP monitor VOIPU VOIPU GKDEBUG Simple GK Debug VOIPCCDEBUG VoIP CC Debug TEXT Text Message CIM Class No Edit PHS...

Страница 46: ...2PSTS p2pStatus Disp DTERMCTRL Dterm Control NWINFO Networking Information TRLHC Trillium HC layer debug information SENDTONE SendTone PRGINFO PRGINFO RL Read LANC Register STATUS Show the Status HEAP...

Страница 47: ...ut of all ISDN activity on the system is turned on Enter ISDN debug mode master current bid xxH master current line xxH The activity of all ISDN blades will be output Mail in 0012 Output of all ISDN a...

Страница 48: ...mber of the ISDN card that the event was sent received on If you have more than one ISDN card in the system the slot and circuit number can be identified by this information The first number is the sl...

Страница 49: ...bug on should only be used in the lab or after normal working hours at a customer site as it causes a large amount of information to be output and can slow the SV8100 Enter Function DIM Output NWINFO...

Страница 50: ...eneral system information including CD CP00 US software version and PAL type Current date time 1 1 2002 TUE 0 17 41 System build date Jul 16 2004 16 56 25 Target is North America Electra Main software...

Страница 51: ...atus of trunk ports 1 through to 10 status trk 01 0a R Slot P To display the information related to the Blade installed into a slot slot info nn Where nn is the slot number 01 to 24 in hexadecimal exa...

Страница 52: ...Timeslot 040H 043H 4 BRIU driver information P To reset the Blade installed in a slot slot reset nn Where nn is the slot number 01 to 10 in hexadecimal The Blade is reset any calls in progress at the...

Страница 53: ...Backup battery normal No power keep requests available Power off request The status of the power switch on the PSU none powered on guarding waiting to power off Power source AC Power source AC Normal...

Страница 54: ...r H 323 for H 323 extensions Enter Function DIM Output IP INFO Displays a list of IP information Usage ip info para para 0 IP Version 2 CAPS Call Info Table Dump 3 IP Station Regist Table Dump 4 VoIPU...

Страница 55: ...3203 SerialPort 257 IP Address 192 168 1 131 Voice Path Port 4000 CALL SIG Port 3458 Terminal Type 2 DtermIP Extension Number 3232 SerialPort 258 IP Address 192 168 100 200 Voice Path Port 4000 CALL S...

Страница 56: ...r 1 30 8 50 RegId2 UserId not REGISTERED to SIP Server 1 30 8 50 RegId3 UserId not REGISTERED to SIP Server 1 30 8 50 RegId4 UserId not REGISTERED to SIP Server 1 30 8 50 RegId5 UserId not REGISTERED...

Страница 57: ...fault Gateway PRG10 12 03 Default Gateway 192 168 1 254 IP ARP Displays the SV8100 ARP Address Resolution Protocol cache This is a table of MAC address to IP Address mappings See below IP ROUTE Displa...

Страница 58: ...299 192 168 100 200 00 60 B9 C4 48 11 81637340 192 168 001 254 00 30 13 16 E8 6F 113785925 192 168 001 030 00 60 B9 C1 B2 30 113749983 192 168 001 040 00 60 B9 C1 C3 BF 113749986 192 168 102 200 00 60...

Страница 59: ...255 127 000 000 001 000 000 000 000 1 192 168 001 000 255 255 255 000 192 168 001 020 000 000 000 000 1 192 168 001 020 255 255 255 255 127 000 000 001 000 000 000 000 1 Default Route 192 168 001 254...

Страница 60: ...90 091 100 101 110 111 120 121 130 131 140 141 150 151 160 161 170 171 180 181 190 191 200 201 210 211 220 221 230 231 240 241 250 251 260 261 270 271 280 281 290 291 300 301 310 311 320 321 330 331 3...

Страница 61: ...00 0000 0000 0000 091 100 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 101 110 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 111 120 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 121 130...

Страница 62: ...ot 02 Busy Slot 03 Busy Slot 04 Busy Slot 05 Busy Slot 06 Busy Slot 07 Busy Slot 08 Busy Slot 09 Busy Slot 10 Busy Slot 11 Busy Slot 12 Busy Slot 13 Busy Slot 14 Busy Slot 15 Busy Slot 16 Busy VoIPU A...

Страница 63: ...fied by the two digits in hexadecimal following the logical port type The two digits are 00 to ff hexadecimal 00 to 255 in decimal example keytelephone port 1 will be 0401 as shown below PORT 0401H ST...

Страница 64: ...elow The port number is identified by the two digits in hexadecimal following the logical port type The two digits are 00 to ff hexadecimal 00 to 255 in decimal example SV8100Net port 01 is 7c01 as sh...

Страница 65: ...speech 18 03 A9 83 81 Channel identification 6C 02 00 81 Calling party number 7C 03 80 90 A3 Low layer compatibility 7D 02 91 81 High layer compatibility R ISDN 15 0B A1 0F 01 01 00 USL 8 1 MORE INFO...

Страница 66: ...81 88 Progress indicator T305 TIMER CLEAR ACD Data Size error or socket close HP_LCD_REQ 0401 0001 0000 0000 0000 ACD Data Size error or socket close S ISDN F4 A1 0C 01 01 00 USL 8 1 RELEASE REQ 08 0...

Страница 67: ...0401H P2 000AH P3 000BH P4 0000H P5 0000H 1 JAN 2002 10 12 EVENT ID 0000H P1 0401H P2 0005H P3 000AH P4 0000H P5 0000H EVENT ID 0000H P1 0401H P2 0000H P3 0001H P4 0000H P5 0000H caps_service Returns...

Страница 68: ...0000H 1 JAN 2002 10 12 EVENT ID 0000H P1 0401H P2 0002H P3 000AH P4 0000H P5 0000H EVENT ID 0000H P1 3415H P2 0000H P3 097FH P4 0000H P5 0000H S ISDN F4 A1 0E 01 01 00 USL 8 1 INFO REQ 08 02 00 04 7B...

Страница 69: ...0401H P3 0C76H P4 0000H P5 0000H EVENT ID 001FH P1 1102H P2 0000H P3 0000H P4 0000H P5 0000H 1 JAN 2002 10 12 EVENT ID 0004H P1 080BH P2 0000H P3 DF080F8H P4 0000H P5 0000H R ISDN 13 0B A1 30 01 01 00...

Страница 70: ...5H STATUS 00C3H 0025H Tone information for port 0C15H Timeslot 0138H Level Tx 20H Rx 20H Current 00F2H Level 20H Sender Not opened EVENT ID 001FH P1 1401H P2 0000H P3 0000H P4 0000H P5 0000H EVENT ID...

Страница 71: ...72 16 0 15 NwInfo Free RsrcID is found port 01 NwInfo cnetwork_pro00 is called prgrd1501 cpp 38 read_s_sta_clip_enable port 0 data 1 NwInfo create_network_packet rsrc_id_w 1 bid 7 rsrc 1 line 1 NwInfo...

Страница 72: ...01 src_port_w 0401 rsrc 1 H323 status 0024 0011 NwInfo CNETWORK_MAIN is called 7c01 NwInfo T305 TIMER CLEAR NwInfo cnetwork_pro10 is called NwInfo get_inter_signal_target 0804H called NwInfo send_inte...

Страница 73: ...IVERGE SV8100 Issue 1 0 System Maintenance Manual 3 33 NwInfo Search Free Resource NwInfo Free resource searching abort signal 0804 NwInfo cnetwork_pro00 is called Networking procedure was not execute...

Страница 74: ...00 07 01 01 02 01 01 24 01 02 2B 11 11 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 A1 Sending complete Tone information for port E001H Timeslot 0101H Level Tx 20H Rx 20H Current 0000H Level 20H S...

Страница 75: ...1 21 01 00 2E 01 00 3B 04 01 04 00 00 07 01 01 02 01 01 24 01 02 2B 11 11 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 0A 04 A2 0A 00 00 03 04 10 08 00 00 response_while_frouting Selfport 7c01 Targ...

Страница 76: ...Issue 1 0 UNIVERGE SV8100 3 36 NOTES...

Страница 77: ......

Страница 78: ...System Maintenance Manual NEC Unified Solutions Inc Issue 1 0...

Отзывы: