UNIVERGE SV8100
Issue 1.0
System Maintenance Manual
2 - 9
Call Dropping
See if problem exists
on all Lines.
Check DC voltages with
a meter and AC power
with a line disturbance
analyzer.
Calls
dropped on
all lines?
Yes
Yes
No
No
All
lines at same
time?
Check outside line key
after call drops.
CO
Line Key
LED Status?
C
heck
CD-4COTB
LED.
Have Telco check line circuits.
Increase Automatic Release
Signal Detection Time. Refer to
PRG 14-02-09.
CD-4COTB
LED Status?
Off
On
Have Telco check
Line circuit(s).
Problem
Solved?
Return Defective blade
for repair.
Perform First Initialization.
Replace CD-CP00-US, and
test system using default
program.
1. Perform Second Initialization.
If trouble persists go to step 2.
2. Replace CD-4COTB
.
Test.
On
Off
Yes
No
C2
Содержание Univerge SV8100
Страница 2: ......
Страница 3: ...System Maintenance Manual INT 2057 UNIV ISSUE 1 0...
Страница 4: ......
Страница 6: ......
Страница 8: ...THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 18: ...Issue 1 0 UNIVERGE SV8100 1 6 Troubleshooting IP on an SV8100 System Figure 1 3 Trace File Example...
Страница 40: ...Issue 1 0 UNIVERGE SV8100 2 22 System Maintenance NOTES...
Страница 76: ...Issue 1 0 UNIVERGE SV8100 3 36 NOTES...
Страница 77: ......
Страница 78: ...System Maintenance Manual NEC Unified Solutions Inc Issue 1 0...